BACKGROUND

The purpose of this study was to evaluate the short- and long-term results of radiofrequency catheter ablation (RFCA) for the treatment of atrial fibrillation (AF) in patients with mitral stenosis (MS) following percutaneous transvenous mitral commissurotomy (PTMC).

METHODS AND

RESULTS

Four patients (2 males, age 59+/-6 years) underwent simultaneous PTMC and pulmonary vein (PV) ablation. All patient had AF and MS (2 had persistent AF >1 month, 2 had paroxysmal AF), and the mean duration of AF was 3.4+/-3.3 years. The mean left atrial dimension was 47+/-7 mm and the mean ejection fraction was 58+/-4%. After PTMC, RFCA was performed in all patients (3 underwent PV isolation and 1 had PV focal ablation). The mitral valve area increased from 1.11 +/-0.19 to 1.90+/-0.20 cm(2) (p < 0.01). The frequency of AF episodes was dramatically reduced in the 2 patients with paroxysmal AF, and the 1 with persistent AF maintained sinus rhythm, but 1 patient with persistent AF developed recurrent AF. No complications or cardiac events occurred in any of the patients.

CONCLUSION

The combination of RFCA and PTMC was safe and feasible, and may be useful in patients with MS and AF.

Для цитирования: Miyaji Kohei, Tada Hiroshi, Ito Sachiko, Naito Shigeto, Yamada Minoru, Hashimoto Tohru, Hoshizaki Hiroshi, Oshima Shigeru, Taniguchi Koichi. Percutaneous transvenous mitral commissurotomy and radiofrequency catheter ablation in patients with mitral stenosis.. Circulation journal : official journal of the Japanese Circulation Society. 2005. DOI: 10.1253/circj.69.1074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.