MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.0886-0440.2003.02065.x

Медицинская библиотека · Journal of cardiac surgery · 2003

Experience of the small size (25 mm) Sorin Bicarbon bileaflet prosthetic valve in patients with small mitral annuli.

Erdil Nevzat, Cetin Levent, Demirkilic Ufuk, Tatar Harun, Uzun Mehmet

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Currently, there is a tendency to use large-size prosthetic valves in mitral position in order to achieve better hemodynamic performance. We aimed to evaluate hemodynamic performance of 25 mm prosthetic valves in mitral position.

METHODS

Between August 1998 and May 2000, a total of 40 patients, 34 women and 6 men (mean age 42 +/- 12 years), underwent mitral valve replacement with 25 mm bileaflet mechanical valve. Preoperative functional capacity was New York Heart Association classes III and IV in 31 patients. Major indication for surgery was severe mitral stenosis in all patients.

RESULTS

Total hospital mortality was 5% (two patients). Mean follow-up period was 14.7 +/- 4.9 months (2 to 23 months). No thromboembolic event, paravalvular leak, mechanical failure, endocarditis were observed during the follow-up period. Postoperatively 92.5% of the patients were in the functional capacity of New York Heart Association class I. Postoperative echocardiographic observations have given an average pulmonary artery pressure of 29 +/- 2 mmHg, effective orifice area as 2.95 +/- 0.1 cm2, and mean prosthetic gradient as 6.5 +/- 2.7 mmHg.

CONCLUSION

In short- and mid-term, small-size (25 mm) Sorin mechanical mitral valves had excellent hemodynamic performance in patients with severe mitral stenosis, moderate or serious pulmonary hypertension, and small mitral annuli, whose body surface area was smaller than 1.6 m2.

Для цитирования: Erdil Nevzat, Cetin Levent, Demirkilic Ufuk, Tatar Harun, Uzun Mehmet. Experience of the small size (25 mm) Sorin Bicarbon bileaflet prosthetic valve in patients with small mitral annuli.. Journal of cardiac surgery. 2003. DOI: 10.1046/j.0886-0440.2003.02065.x.