MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.0742-2822.2004.03064.x

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2004

Left ventricular long-axis function is reduced in patients with rheumatic mitral stenosis.

Ozer Necla, Can Ilknur, Atalar Enver, Sade Elif, Aksöyek Serdar, Ovünç Kenan, Aytemir Kudret, Tokgözoğlu Lale, Ozmen Ferhan, Kes Sirri

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Left ventricular long-axis function evaluated by M-mode or tissue Doppler echocardiography has been shown to be useful indexes of left ventricular systolic function; however it has not been evaluated in patients with mitral stenosis. We examined the left ventricular long-axis function of the patients with pure mitral stenosis and normal global systolic function as assessed by fractional shortening of the left ventricle (LV). Fifty-two patients with pure mitral stenosis and twenty-two healthy controls were evaluated by echocardiography. Although there was no statistically significant difference in global systolic function, M-mode derived systolic motion of the septal side and (12 +/- 3 vs 14.4 +/- 1.5 mm, P = 0.016) the lateral side of mitral annulus (13.2 +/- 3 vs 16.8 +/- 2 mm, P = 0.001) were both significantly lower in the patients with mitral stenosis than control subjects. Similarly tissue Doppler systolic velocity of the septal annulus (7.6 +/- 1.1 vs 10.4 +/- 3.2 cm/s, P = 0.03) and lateral mitral annulus (7.6 +/- 1.1 vs 10.4 +/- 3.2 cm/s, P = 0.003) were also significantly lower in patients with mitral stenosis than in controls. There was a statistically significant correlation between septal annular motion and annular velocity (r = 0.643, P = 0.002). Septal annular motion and annular velocity were also correlated with left atrial ejection fraction (r = 0.338, P = 0.005 and r = 0.676, P = 0.001, respectively). Thus, patients with mitral stenosis had significantly impaired long-axis function evaluated by M-mode or tissue Doppler echocardiography despite normal global systolic function.

Для цитирования: Ozer Necla, Can Ilknur, Atalar Enver, Sade Elif, Aksöyek Serdar, Ovünç Kenan, Aytemir Kudret, Tokgözoğlu Lale, Ozmen Ferhan, Kes Sirri. Left ventricular long-axis function is reduced in patients with rheumatic mitral stenosis.. Echocardiography (Mount Kisco, N.Y.). 2004. DOI: 10.1111/j.0742-2822.2004.03064.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.