Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2023

Overnight 1-mg Dexamethasone Suppression Test for Screening Cushing Syndrome and Mild Autonomous Cortisol Secretion (MACS): What Happens when Serum Dexamethasone Is Below Cutoff? How Frequent Is it?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Farinelli Denise G, Oliveira Kelly C, Hayashi Lilian F, Kater Claudio E

Аннотация

OBJECTIVE: To determine the frequency of "invalid" 1-mg overnight dexamethasone (Dex) suppression tests (DSTs) (1-mg DST) on a large series of patients investigated for hypercortisolism and examine the interference of substances and clinical conditions that may explain low serum Dex levels.

METHODS: A retrospective analysis of 1300 Dex-controlled 1-mg DST applied to patients screened for Cushing syndrome or mild autonomous cortisol secretion in a single center for which there were identified invalid tests and distinctive characteristics that may have interfered with the outcome.

RESULTS: Among all tests, 146 (11.2%) were considered invalid (serum Dex levels <140 ng/dL, 36 [24.7%] of which were undetectable [<19.5 ng/dL]). In the Dex-undetectable group, 17% failed to take Dex correctly, 25% were on glucocorticoids (GCs), and 20% were on anticonvulsants and moderate CYP3A4 inducers. In the remaining 110 tests (serum Dex 20-140 ng/dL), 6.5% did not take Dex or were using GC, 22% were on anticonvulsants or CYP3A4 inducers, and another 13% had previous gastrointestinal tract abnormalities impairing drug absorption.

CONCLUSION: Inappropriately low serum Dex levels during the 1-mg DST may lead to false-positive results. This is associated with recurrent use of CYP3A4-inducing drugs and/or gastrointestinal abnormalities. When serum Dex is undetectable, the key reason is failure to take the medication or the use of GC (when cortisol is suppressed). Simultaneous measurement of serum cortisol and Dex allows for DST validation, improving its accuracy and avoiding unnecessary repetitions. Adherence to verbal/written recommendations and actual use of medication are critical for interpreting the test.