Journal of refractive surgery (Thorofare, N.J. : 1995) · 1999
Corneal dynamics after single interrupted suture removal following penetrating keratoplasty.
Клиническое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Solomon A, Siganos C S, Frucht-Pery J
Аннотация
PURPOSE: To evaluate corneal topographic changes after removal of a single interrupted suture in patients who underwent keratoplasty for keratoconus.
METHODS: Fifteen interrupted sutures in 15 eyes after keratoplasty were removed to control astigmatism in a prospective clinical study. Videokeratography using an EyeSys Corneal Analysis System was performed before suture removal, and 1 hour, 1 day, 1 week, and 2 to 4 weeks after suture removal. Changes in dioptric power and axis of the steepest and flattest semimeridians were evaluated.
RESULTS: The range of the dioptric change of the steepest semimeridian was from -0.43+/-0.34 D during the first hour to +0.70+/-0.39 D from 1 day to 1 week. The largest axis change of the steepest semimeridian (17.1 degrees+/-5.6 degrees, range 1 degree to 66 degrees ) occurred during the first hour (P = .006). The largest surgically induced vectorial change occurred during the first hour (16.10 @ 10.5 ), while relative stability of the steepest semimeridian was observed during the rest of the study period. Changes in power and axis of the flattest semimeridian were also demonstrated. A variety of topographic corneal patterns were demonstrated following suture removal, indicating unpredictable change of astigmatism.
CONCLUSIONS: The steepest semimeridian of the central 3-mm zone showed maximal vectorial change 1 hour following suture removal. Reciprocal changes occurred at the same time in the flattest semimeridian. The response of the corneal surface to suture removal is unpredictable and complex.
METHODS: Fifteen interrupted sutures in 15 eyes after keratoplasty were removed to control astigmatism in a prospective clinical study. Videokeratography using an EyeSys Corneal Analysis System was performed before suture removal, and 1 hour, 1 day, 1 week, and 2 to 4 weeks after suture removal. Changes in dioptric power and axis of the steepest and flattest semimeridians were evaluated.
RESULTS: The range of the dioptric change of the steepest semimeridian was from -0.43+/-0.34 D during the first hour to +0.70+/-0.39 D from 1 day to 1 week. The largest axis change of the steepest semimeridian (17.1 degrees+/-5.6 degrees, range 1 degree to 66 degrees ) occurred during the first hour (P = .006). The largest surgically induced vectorial change occurred during the first hour (16.10 @ 10.5 ), while relative stability of the steepest semimeridian was observed during the rest of the study period. Changes in power and axis of the flattest semimeridian were also demonstrated. A variety of topographic corneal patterns were demonstrated following suture removal, indicating unpredictable change of astigmatism.
CONCLUSIONS: The steepest semimeridian of the central 3-mm zone showed maximal vectorial change 1 hour following suture removal. Reciprocal changes occurred at the same time in the flattest semimeridian. The response of the corneal surface to suture removal is unpredictable and complex.