MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/eye.1998.155

Медицинская библиотека · Eye (London, England) · 1998

Corneal endothelial specular microscopy following deep lamellar keratoplasty with lyophilised tissue.

Morris E, Kirwan J F, Sujatha S, Rostron C K

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the corneal endothelial cell density following deep lamellar keratoplasty (DLK) carried out by air dissection and with the transplantation of lyophilised tissue.

METHOD: Contact endothelial specular microscopy was carried out on a series of patients who had undergone DLK with a minimum of 1 year post-operative follow-up.

RESULTS

Twenty eyes of 18 patients were examined at follow-up times ranging from 1 to 8 years post-operatively (mean 3 years). Indications for surgery were: keratoconus (n = 12), herpes simplex virus (HSV) keratitis (n = 1), herpes zoster ophthalmicus (HZO) keratitis (n = 1), lipid keratopathy (n = 2), lattice dystrophy (n = 1) and corneal scarring (n = 3). Overall, mean post-operative cell density was 2417 cells/mm2 (range 928-3656 cells/mm2). In eyes with pathological conditions not likely to have affected the endothelial cell density, such as keratoconus or lattice degeneration, the mean cell density was 2837 cells/mm2 (range 1030-3656 cells/mm2).

CONCLUSIONS

In patients undergoing DLK for conditions such as keratoconus the post-operative cell density was at a normal level in the majority of cases. Cell loss through this surgical intervention thus appears generally to be small. The prospect for long-term survival of these grafts is good.

Для цитирования: Morris E, Kirwan J F, Sujatha S, Rostron C K. Corneal endothelial specular microscopy following deep lamellar keratoplasty with lyophilised tissue.. Eye (London, England). 1998. DOI: 10.1038/eye.1998.155.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.