Медицинская библиотека · Ophthalmic surgery and lasers · 1998

Graft decentration in penetrating keratoplasty: nonmechanical trephination with the excimer laser (193 nm) versus the motor trephine.

Langenbucher A, Seitz B, Kus M M, Vilchis E, Naumann G O

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

Graft decentration is an obvious cause of postkeratoplasty astigmatism. The purpose of this study was to compare graft decentration after nonmechanical trephination with the excimer laser (193 nm) with that after mechanical motor-trephination in 50 consecutive patients with Fuchs' dystrophy and 50 patients with keratoconus.

PATIENTS AND

METHODS

To determine decentration in absolute values and clock hours, a postoperative slide was projected with a fixed magnification onto a pattern with circles corresponding to the trephination margin. Using a second transparent and movable pattern with concentric circles and ellipses, the authors measured the amount and direction of decentration relative to the limbus and to the pupil. In addition, the keratometric astigmatism and the refractive cylinder were assessed. In this prospective study, the patients were assigned randomly to either method of trephination.

RESULTS

The decentration was significantly lower (P < .002) with excimer laser trephination (0.23 +/- 0.26 mm, relative to the limbus; 0.33 +/- 0.26 mm, relative to the pupil) than with mechanical trephination (0.58 +/- 0.23 mm, relative to the limbus [P < .01]; 0.64 +/- 0.24 mm, relative to the pupil [P < .005]). There was no significant difference between the results obtained in patients with Fuchs' dystrophy and those of patients with keratoconus. The preferred direction of decentration relative to the pupil was the lower quadrants. There was a mild correlation between net astigmatism and the absolute value of decentration. However, with sutures in place, there were no significant differences in the keratometric net astigmatism between mechanical and nonmechanical trephination (P = .16) or between Fuchs' dystrophy and keratoconus (P = .18).

CONCLUSIONS

The results indicate that the amount of decentration can be reduced by specific techniques associated with nonmechanical trephination. This might have a favorable impact on the residual astigmatism after suture removal.

Для цитирования: Langenbucher A, Seitz B, Kus M M, Vilchis E, Naumann G O. Graft decentration in penetrating keratoplasty: nonmechanical trephination with the excimer laser (193 nm) versus the motor trephine.. Ophthalmic surgery and lasers. 1998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.