DOI 10.1097/00006324-199612000-00001
Keratoconus detection based on videokeratoscopic height data.
Аннотация
PURPOSE: To develop a videokeratoscopic-based keratoconus detection scheme that avoids the ambiguity of dioptric power definitions and videokeratoscope design.
METHODS
Corneal height data obtained with a commercial videokeratoscope are decomposed into the set of orthogonal Zernike polynomials. Expansion coefficients of a "normal" group and a keratoconus group are compared to find significant differences. Elevated Zernike terms are used to detect the disease in these populations. The performance of this detection scheme is compared to other videokeratoscopic keratoconus Indices.
RESULTS
Two low-order Zernike polynomial terms are identified as being elevated in keratoconus patients and combined to form a new detection index. This index performed at least as well as keratoconus detection schemes based on the inferior-superior (I-S) value, the steepest radial axes (SRAX), and the Surface Asymmetry Index (SAI) for the samples studied.
CONCLUSION
The proposed Zernike scheme offers a potentially viable algorithm for detecting keratoconus that avoids the ambiguities of dioptric power definitions and is independent of videokeratoscope design.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.