MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2334/josnusd.49.207

Медицинская библиотека · Journal of oral science · 2007

Preparation time and sealing effect of cavities prepared by an ultrasonic device and a high-speed diamond rotary cutting system.

Vieira Aurea S B, dos Santos Márcia P A, Antunes Lívia A A, Primo Laura G, Maia Lucianne C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to compare a high-speed handpiece to an ultrasonic device regarding the time taken for cavity preparation in bovine incisor teeth (n = 12), and to evaluate microleakage after the restorations. Two cylindrical cavities each were prepared on the labial surfaces of 12 teeth. One of them was made with a diamond tip in group 1 (G(1) = 12) coupled with a high-speed handpiece, and the other with a chemical vapor deposition (CVD) tip in group 2 (G(2) = 12) coupled with an ultra-sound device (n = 24). The time taken for each preparation was measured with a stopwatch. The cavities were treated with adhesive (Scotchbond Multipurpose, 3M), restored with composite (Filtek Z250, 3M), finished and polished, and then the prepared teeth were immersed in a 50% silver nitrate solution. The samples were cut in the mesio-distal direction and evaluated for microleakage. Data were analyzed using the Wilcoxon test (P < 0.01). The results revealed that the time taken to prepare cavities was 7.9 times shorter in G(1). There was no microleakage in 100% of the samples indicated by the absence of dye penetration in G(1), and 46% in G(2). It was concluded that the performance of the high-speed handpiece was better than that of the oscillatory system, in terms of both the time taken for preparation and the microleakage.

Для цитирования: Vieira Aurea S B, dos Santos Márcia P A, Antunes Lívia A A, Primo Laura G, Maia Lucianne C. Preparation time and sealing effect of cavities prepared by an ultrasonic device and a high-speed diamond rotary cutting system.. Journal of oral science. 2007. DOI: 10.2334/josnusd.49.207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.