Indian journal of ophthalmology · 2019
Dopamine levels in human tear fluid.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sharma Niyati Seshagiri, Acharya Suraj Kumar, Nair Archana Padmanabhan, Matalia Jyoti, Shetty Rohit, Ghosh Arkasubhra, Sethu Swaminathan
Аннотация
PURPOSE: To determine the levels of dopamine in tear fluid and demonstrate the use of tear fluid as a non-invasive source for dopamine measurements in humans.
METHODS: The study cohort included 30 clinically healthy individuals without any pre-existing ocular or systemic conditions. Matched tear fluid (using Schirmer's strips and capillary tubes) and plasma were collected from the subjects. Dopamine levels were evaluated using direct competitive chemiluminescent enzyme-linked immunosorbent assay (ELISA), dopamine kit (Cloud Clone Corp, TX, USA).
RESULTS: Significantly higher dopamine levels were found in the tear fluid compared to plasma in the study subjects. The level of dopamine was 97.2 ± 11.80 pg/ml (mean ± SEM), 279 ± 14.8 pg/ml (mean ± SEM), and 470.4 ± 37.64 pg/ml (mean ± SEM) in the plasma and in the tears collected using Schirmer's strips and capillary tubes, respectively.
CONCLUSION: Dopamine was detectable in all the tear fluid samples tested and was also found to be at a higher concentration than in plasma samples. Tear fluid can be used as a non-invasive sample source to monitor dopamine levels.
METHODS: The study cohort included 30 clinically healthy individuals without any pre-existing ocular or systemic conditions. Matched tear fluid (using Schirmer's strips and capillary tubes) and plasma were collected from the subjects. Dopamine levels were evaluated using direct competitive chemiluminescent enzyme-linked immunosorbent assay (ELISA), dopamine kit (Cloud Clone Corp, TX, USA).
RESULTS: Significantly higher dopamine levels were found in the tear fluid compared to plasma in the study subjects. The level of dopamine was 97.2 ± 11.80 pg/ml (mean ± SEM), 279 ± 14.8 pg/ml (mean ± SEM), and 470.4 ± 37.64 pg/ml (mean ± SEM) in the plasma and in the tears collected using Schirmer's strips and capillary tubes, respectively.
CONCLUSION: Dopamine was detectable in all the tear fluid samples tested and was also found to be at a higher concentration than in plasma samples. Tear fluid can be used as a non-invasive sample source to monitor dopamine levels.