MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-36858-y

Медицинская библиотека · Scientific reports · 2023

GATS tag system is compatible with biotin labelling methods for protein analysis.

Yamada Kohdai, Soga Fumiya, Tokunaga Soh, Nagaoka Hikaru, Ozawa Tatsuhiko, Kishi Hiroyuki, Takashima Eizo, Sawasaki Tatsuya

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Polypeptide tags and biotin labelling technologies are widely used for protein analyses in biochemistry and cell biology. However, many peptide tag epitopes contain lysine residues (or amino acids) that are masked after biotinylation. Here, we propose the GATS tag system without a lysine residue and with high sensitivity and low non-specific binding using a rabbit monoclonal antibody against Plasmodium falciparum glycosylphosphatidylinositol (GPI)-anchored micronemal antigen (PfGAMA). From 14 monoclonal clones, an Ra3 clone was selected as it recognized an epitope-TLSVGVQNTF-without a lysine residue; this antibody and epitope tag set was called the GATS tag system. Surface plasmon resonance analysis showed that the tag system had a high affinity of 8.71 × 10-9 M. GATS tag indicated a very low background with remarkably high sensitivity and specificity in immunoblotting using the lysates of mammalian cells. It also showed a high sensitivity for immunoprecipitation and immunostaining of cultured human cells. The tag system was highly sensitive in both biotin labelling methods for proteins using NHS-Sulfo-biotin and BioID (proximity-dependent biotin identification) in the human cells, as opposed to a commercially available tag system having lysine residues, which showed reduced sensitivity. These results showed that the GATS tag system is suitable for methods such as BioID involving labelling lysine residues.

Для цитирования: Yamada Kohdai, Soga Fumiya, Tokunaga Soh, Nagaoka Hikaru, Ozawa Tatsuhiko, Kishi Hiroyuki, Takashima Eizo, Sawasaki Tatsuya. GATS tag system is compatible with biotin labelling methods for protein analysis.. Scientific reports. 2023. DOI: 10.1038/s41598-023-36858-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.