OBJECTIVE

To compare error rates of three existing methods of predicting the gastric tube insertion length in a group of neonates <1 month corrected age: age-related, height-based (ARHB); direct distance nose-ear-xiphoid (NEX); and direct distance nose-ear-mid-umbilicus (NEMU).

DESIGN

Randomized controlled trial.

SETTING

Five neonatal care units in a large midwestern city.

PARTICIPANTS

One hundred and seventy-three hospitalized neonates.

METHODS

Neonates were randomly assigned to one of three groups: ARHB, NEX, or NEMU. For primary analysis, only tubes placed too high with the tube tip in the esophagus or at the gastroesophageal junction were considered to be misplaced. For secondary analysis, a stricter definition was used, and low placements (pylorus or duodenum) were also considered to be misplaced. All radiographs were blinded and read by a pediatric radiologist.

RESULTS

For the primary analysis, the differences in percentages of correctly placed tubes among the three methods was statistically significant (χ(2) =34.45; p<.0001), with NEMU and ARHB more accurate than NEX (NEMU χ(2) =18.59, p<.0001; ARHB χ(2) =21.34, p<.0001). Using the stricter definition for placement, ARHB was not significantly different from NEX (p=.0615). A new ARHB equation was developed specific for neonates <1 month corrected age.

CONCLUSIONS

Direct distance nose-ear-xiphoid should no longer be used as an nasogastric/orogastric (NG/OG) tube insertion-length predictor in neonates. Either NEMU for NG/OG tubes or the new ARHB equation for NG tubes should be used.

Для цитирования: Cirgin Ellett Marsha L, Cohen Mervyn D, Perkins Susan M, Smith Coral E, Lane Kathleen A, Austin Joan K. Predicting the insertion length for gastric tube placement in neonates.. Journal of obstetric, gynecologic, and neonatal nursing : JOGNN. 2011. DOI: 10.1111/j.1552-6909.2011.01255.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.