m+Medelevator.RU
← Поиск публикаций
Journal of immunological methods · 2023

Clinical evaluation of commercial SARS-CoV-2 serological assays in a malaria endemic setting.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dabitao Djeneba, Shaw-Saliba Kathryn, Konate Drissa S, Highbarger Helene C, Lallemand Perrine, Sanogo Ibrahim, Rehman Tauseef, Wague Mamadou, Coulibaly Nadie, Kone Bourahima, Baya Bocar, Diakite Seidina A S, Samake Seydou, Akpa Esther, Tounkara Moctar, Laverdure Sylvain, Doumbia Seydou, Lane H Clifford, Diakite Mahamadou, Dewar Robin L

Аннотация

The levels of immune response to SARS-CoV-2 infection or vaccination are poorly understood in African populations and is complicated by cross-reactivity to endemic pathogens as well as differences in host responsiveness. To begin to determine the best approach to minimize false positive antibody levels to SARS-CoV-2 in an African population, we evaluated three commercial assays, namely Bio-Rad Platelia SARS-CoV-2 Total Antibody (Platelia), Quanterix Simoa Semi-Quantitative SARS-CoV-2 IgG Antibody Test (anti-Spike), and the GenScript cPass™ SARS-CoV-2 Neutralization Antibody Detection Kit (cPass) using samples collected in Mali in West Africa prior to the emergence of SARS-CoV-2. A total of one hundred samples were assayed. The samples were categorized in two groups based on the presence or absence of clinical malaria. Overall, thirteen out of one hundred (13/100) samples were false positives with the Bio-Rad Platelia assay and one of the same one hundred (1/100) was a false positive with the anti-Spike IgG Quanterix assay. None of the samples tested with the GenScript cPass assay were positive. False positives were more common in the clinical malaria group, 10/50 (20%) vs. the non-malaria group 3/50 (6%); p = 0.0374 using the Bio-Rad Platelia assay. Association between false positive results and parasitemia by Bio-Rad remained evident, after adjusting for age and sex in multivariate analyses. In summary, the impact of clinical malaria on assay performance appears to depend on the assay and/or antigen being used. A careful evaluation of any given assay in the local context is a prerequisite for reliable serological assessment of anti-SARS-CoV-2 humoral immunity.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты