MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.accpm.2024.101419

Медицинская библиотека · Anaesthesia, critical care & pain medicine · 2024

Propofol does not alter the protein binding and unbound concentration of lidocaine at clinically targeted plasma concentrations in vitro - A short communication.

Tognolini Angela R, Roberts Jason A, Pandey Saurabh, Wallis Steven C, Eley Victoria A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intravenous lidocaine is increasingly used as an analgesic adjunct during general anaesthesia. Lidocaine is highly protein-bound and changes to binding can alter drug efficacy or toxicity. We aimed to measure the effect of various propofol and lidocaine plasma concentration combinations on the protein binding and concentration of lidocaine in vitro.

METHODS

Known targeted concentrations of propofol and lidocaine were added to drug-free human plasma in vitro. Samples were prepared and analysed in various clinically relevant concentration combinations; propofol at 0, 2, 4 and 6 µg/mL, and lidocaine at 1, 3 and 5 µg/mL. The total and unbound concentrations of lidocaine were measured by ultra-high performance liquid chromatography-mass spectrometry and percentage protein binding was determined. Data were presented as mean and standard deviation (SD) and differences between groups analysed.

RESULTS

The overall mean protein binding of lidocaine was 68.8% (SD 5.5, range 57.5-80.9%). Beta regression analysis revealed no statistically significant difference in lidocaine percentage binding across a range of propofol and lidocaine concentration combinations.

CONCLUSION

Propofol did not alter the unbound and free pharmacologically active proportion of lidocaine at different clinically targeted concentrations of propofol and lidocaine in plasma in vitro. The percentage of plasma protein binding of lidocaine in this study was consistent with previously published results.

Для цитирования: Tognolini Angela R, Roberts Jason A, Pandey Saurabh, Wallis Steven C, Eley Victoria A. Propofol does not alter the protein binding and unbound concentration of lidocaine at clinically targeted plasma concentrations in vitro - A short communication.. Anaesthesia, critical care & pain medicine. 2024. DOI: 10.1016/j.accpm.2024.101419.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.