m+Medelevator.RU
← Поиск публикаций
Geriatrics & gerontology international · 2016

Catheter replacement structure in home medical care settings and regional characteristics in Tokyo and three adjoining prefectures.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kimura Takuma, Yoshie Satoru, Tsuchiya Rumiko, Kawagoe Shohei, Hirahara Satoshi, Iijima Katsuya, Akahoshi Toru, Tsuji Tetsuo

Аннотация

AIM: The present study investigated the association between the structure of catheter replacement services in home medical care settings and regional characteristics.

METHODS: An anonymous self-administered questionnaire was carried out from August to September 2013. Participants were physicians from 5338 clinics that provided medical care services at home, and nurses from 1619 home-visit nursing stations in Tokyo and three adjoining prefectures. The questionnaire covered catheter replacement (gastrostomy tubes, nasogastric tubes, tracheal cannulas) during home medical care, and the professions of those who replaced urethral catheters for male and female patients. Regions were divided into two groups (higher- and lower-density regions) based on the number of clinics, number of home-visit nursing stations and the ratio of the population aged ≥65 years. The rates of respondents that reported catheter replacement was usually executed, and those who reported catheters were replaced by "physicians in principle" were compared between the groups.

RESULTS: Responses were received from 842 clinics (16.3%) and 499 home-visit nursing stations (31.4%). In the higher-density regions, the rate of physicians who reported urethral catheters for male patients were replaced by "physicians in principle" was significantly higher than in the lower-density regions (P < 0.001). In the lower-density regions, the rate of nurses who reported urethral catheters for male patients were replaced by "nurses in principle" was significantly higher compared with the higher-density regions (P < 0.016).

CONCLUSIONS: In home medical care settings, urethral catheters for male patients are replaced by nurses in regions where physician resources are limited. Geriatr Gerontol Int 2017; 17: 628-636.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты