MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/end.2016.0288

Медицинская библиотека · Journal of endourology · 2016

Safety and Efficacy of GreenLight XPS Laser Vapoenucleation in Prostates Measuring Over 150 mL.

Stone Benjamin V, Chughtai Bilal, Forde James C, Tam Andrew W, Lewicki Patrick, Te Alexis E

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The GreenLight™ XPS Laser System (GL-XPS) is a safe and efficacious treatment for lower urinary tract symptoms due to benign prostatic hyperplasia (BPH), but there is limited evidence on its use in prostates over 150 mL. We demonstrate the safety and efficacy of the GL-XPS system using a vapoenucleation technique in prostate glands measuring over 150 mL.

METHODS

We prospectively collected data on all consecutive patients with prostates measuring over 150 mL on transrectal ultrasound treated with the GL-XPS (AMS, Inc., Minnetonka, MN) at a tertiary referral center from September 2011 to October 2015. Data collected include prostate volume, International Prostate Symptom Score (IPSS) and quality of life (QoL) scores, maximum urinary flow rate (Qmax), postvoid residual (PVR), prostate-specific antigen, complications, and reintervention rates.

RESULTS

Seventy male patients with a median prostate size of 202 mL (range 152-376 mL) were included. There were 41 patients (59%) in preoperative urinary retention with an indwelling catheter preoperatively. Thirty-seven (53%) patients were American Society of Anesthesiologists (ASA) class 2 and 33 (47%) were class 3. Median operative time was 180 minutes, laser time 97 minutes, energy utilization 674 kJ, and energy density 3.3 kJ/mL, with median 3 fibers used per case. Median length of stay and length of catheterization were 1 day. IPSS and QoL scores demonstrated significant improvements from baseline at all endpoints, improving from 16 to 3.5 and from 4 to 1 at 24 months, respectively (p = 0.001). At 12 months, Qmax and PVR improved from 10.1 to 22.4 mL/s (p = 0.043) and from 84 to 31.4 mL (p = 0.015), respectively. Retreatment was required in two patients (2.9%).

CONCLUSION

GL-XPS vapoenucleation provided durable subjective and objective improvements in symptoms and voiding parameters, with no serious adverse events in men with prostates >150 mL.

Для цитирования: Stone Benjamin V, Chughtai Bilal, Forde James C, Tam Andrew W, Lewicki Patrick, Te Alexis E. Safety and Efficacy of GreenLight XPS Laser Vapoenucleation in Prostates Measuring Over 150 mL.. Journal of endourology. 2016. DOI: 10.1089/end.2016.0288.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.