Intractable Hematuria After Left Ventricular Assist Device Implantation: Can Lessons Learned from Gastrointestinal Bleeding Be Applied?

Son Andre Y, Zhao Lee, Reyentovich Alex, Deanda Abe, Balsam Leora B

СтатьяПеревод пока не подготовлен

Аннотация

Patients with continuous-flow left ventricular assist devices (CF-LVADs) are at increased risk of bleeding. We reviewed our institutional experience with bleeding in the urinary tract after CF-LVAD implantation and quantified the impact on hospital resource utilization in comparison with bleeding in the gastrointestinal (GI) tract, the most commonly reported mucosal site of bleeding after LVAD implantation. Records were retrospectively reviewed for patients undergoing CF-LVAD implantation at our institution between October 2011 and April 2015. Major adverse events of gross hematuria and GI bleeding were identified, and patient demographics and hospital course were reviewed. Gross hematuria occurred in 3 of the 35 patients (8.6%) and in 5.1% of all hospitalizations for CF-LVAD patients. Severe hematuria occurred after traumatic urethral catheterization, urinary retention, or urologic surgery. Hospitalization for hematuria was six times less likely than hospitalization for GI bleeding; however, hematuria hospitalizations lasted 3.2 times longer than GI bleeding hospitalizations (17.0 vs. 5.3 days). Late recurrent gross hematuria occurred in all cases, with rehospitalization occurring after 109 ± 53 days. In conclusion, gross hematuria is an infrequent but morbid bleeding complication in CF-LVAD patients. Strategies to avoid this complication include strict avoidance of traumatic urethral catheterization and urinary retention in high-risk patients.

Для цитирования: Son Andre Y, Zhao Lee, Reyentovich Alex, Deanda Abe, Balsam Leora B. Intractable Hematuria After Left Ventricular Assist Device Implantation: Can Lessons Learned from Gastrointestinal Bleeding Be Applied?. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2016. DOI: 10.1097/mat.0000000000000276.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.