OBJECTIVE

To investigate the correlations between retinal fluorescein angiography and blood viscosity and other factors in patients with primary open angle glaucoma (POAG).

METHODS

Multiple stepwise regression analysis was made to approach the correlation between each of the following blood vessel filling times: the arm-choroid (A-CT), arm-retinal artery (A-AT), and retinal artery-venous (A-VT) of the fundus fluorescein angiography (FFA) in 122 eyes with POAG and each of the following related factors in hemorheology: whole blood apparent viscosity at low, medium and high shear rates, plasma viscosity and hematocrit. Also, the same analysis was applied to investigate the correlation between each of the A-AT, A-VT of the FFA in 70 eyes with POAG and each of the following factors: systolic blood pressure, diastolic blood pressure, age and the whole blood apparent viscosity at low shear rate.

RESULTS

The whole blood apparent viscosity at low shear rate was closely related to A-CT and A-AT, while hematocrit was closely related to A-VT of the FFA. The whole blood apparent viscosity at low shear rate and age, especially whole blood apparent viscosity, was closely related to A-AT, A-VT of the FFA.

CONCLUSION

The blood viscosity can affect the filling times of the FFA in POAG.

Для цитирования: Liu X, Zhou W, Ye T. [Correlations between retinal fluorescein angiography and blood viscosity and other factors in patients with primary open angle glaucoma].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.