MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf00212949

Медицинская библиотека · International ophthalmology · 1996

Evaluation of the peripapillary circulation in healthy and glaucoma eyes with scanning laser Doppler flowmetry.

Holló G, Greve E L, van den Berg T J, Vargha P

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

In order to study peripapillary perfusion, one randomly selected eye of 34 of healthy volunteers and 40 glaucoma patients (27 suffering from primary open-angle glaucoma (POAG) 10 from normal pressure glaucoma (NPG) nd three from other types of glaucoma) was studied with a Heidelberg Retina Flowmeter. Temporal flow adjacent to the disc edge was significantly higher than the nasal flow (p < 0.01). It was reduced significantly in myopia both in controls (p < 0.05) and in glaucoma patients (p < 0.001). However, there was no difference between either controls and glaucoma patients or between POAG and NPG patients. It was independent of treatment type in glaucoma. Within the temporal peripapillary area extremely high flow values (values higher than the mean + 2 SD of the corresponding individual retinal flow) seemed to represent deep peripapillary vascular rings. They were significantly more frequent in glaucoma (72%) than in healthy volunteers (44%, p < 0.05). Their frequency was 83% in myopic and 23% in non-myopic eyes in the control group (p < 0.001). However, in glaucoma patients they were common both in myopic eyes (71%) and in non-myopic ones (75%). The results suggest that capillary perfusion adjacent to the temporal edge of the disc is significantly reduced in myopia. Deep peripapillary vascular structures can be measured on images focused on the surface of the retina, especially if the retina is thinner than normal (healthy myopic eyes and glaucomatous eyes independently of the refraction). This may mask a deficient function of the retinal capillary bed.

Для цитирования: Holló G, Greve E L, van den Berg T J, Vargha P. Evaluation of the peripapillary circulation in healthy and glaucoma eyes with scanning laser Doppler flowmetry.. International ophthalmology. 1996. DOI: 10.1007/bf00212949.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.