MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.artd.2022.08.006

Медицинская библиотека · Arthroplasty today · 2022

Systemic Metal Ion Concentrations in Patients With Hip and Knee Megaprostheses: A Prospective Cohort Study.

de Smidt Kiki Q, Spierenburg Geert, Evenhuis Richard E, Bosma Sarah E, van der Wal Robert J P, Broekhuis Demien, van de Sande Michiel A J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Local tissue and serum metal ions have been shown to be elevated in some metal-on-metal and metal-on-polyethylene joint replacements. Local elevations have been linked to adverse local tissue reactions in some patients, and systemic elevation has been less commonly implicated cardiac and neurologic issues. Using a prospective study design, we aimed to identify the changes in serum metal ion levels after hip or knee megaprosthesis reconstruction. Furthermore, we will evaluate the occurrence of adverse effects and complications, possibly linked to metal ion elevation.

METHODS

Fourteen consecutive patients receiving a Modular Universal Tumor Revision System megaprosthesis were enrolled. Blood samples were collected preoperatively and postoperatively to determine the serum ion concentrations of aluminum, chromium, cobalt, and silver. To evaluate the safety of the megaprostheses and the subsequently possible related (elevated) serum metal ion concentrations, all adverse effects and complications were registered until last outpatient clinic visit at the time of this study.

RESULTS

Compared to the preoperative median serum concentrations, the postoperative median serum concentrations of chromium, silver, and cobalt increased 11-fold, 62-fold, and 64-fold, respectively. The median serum concentration of aluminum increased with 16%. Elevations were primarily noted in patients with knee prostheses. Eight patients had no adverse effects or complications during the period between preoperative and postoperative blood sampling. One adverse effect directly related to the serum metal ion concentrations, namely argyria, was observed.

CONCLUSIONS

This study documents significantly elevated concentrations of the metal ions, but only one adverse effect directly related to the metal ion concentrations was observed. Future studies are needed to further assess the impact of elevated metal ion levels after megaprostheses, specifically knee implants, which are metal-on-metal.

Для цитирования: de Smidt Kiki Q, Spierenburg Geert, Evenhuis Richard E, Bosma Sarah E, van der Wal Robert J P, Broekhuis Demien, van de Sande Michiel A J. Systemic Metal Ion Concentrations in Patients With Hip and Knee Megaprostheses: A Prospective Cohort Study.. Arthroplasty today. 2022. DOI: 10.1016/j.artd.2022.08.006.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.