MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/atm-22-107

Медицинская библиотека · Annals of translational medicine · 2022

Visual function assessment of posterior-chamber phakic implantable collamer lenses with a central port.

Bai Zongxia, Nie Danyao, Zhang Jing, Hu Huiling, Sun Liangnan, Zeng Kun, Wang Jiantao, Liu Xinhua

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To investigate the short-term visual function of the V4c implantable collamer lens (ICL) for myopia using a Binoptometer 4P.

METHODS

Eighty eyes from 40 patients (age, 28.75±6.57 years) who underwent ICL V4c implantation at Shenzhen Eye Hospital from August 2020 to June 2021 were enrolled. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), subjective manifest refraction, intraocular pressure (IOP), and corneal endothelial cell density (ECD) were evaluated 1 month after surgery. Corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), contrast sensitivity (CS), near stereoacuity (NSA), twilight vision, and glare sensitivity were measured using a Binoptometer 4P.

RESULTS

The average logMAR (logarithmic minimum angle of resolution) UCVA postoperative was 0.07±0.13, which was significantly better than the preoperative BCVA (P=0.028). At 1 month postoperatively, the mean safety and efficacy indexes were 1.14±0.24 and 0.98±0.16, respectively. The mean spherical equivalent (SE) of all eyes was -8.98±3.20 D preoperatively, and -0.16±0.48 D postoperatively. None of the patients lost one or more lines of BCVA, 62.1% remained unchanged, 10.6% gained one line, and 27.3% gained two or more lines. CDVA, CNVA, CS, and NSA of both eyes were measured using a Binoptometer 4P, which were significantly better than the preoperative values. In addition, some patients had subjective symptoms in the early postoperative period, such as halo, glare, etc.

CONCLUSIONS

ICL V4c implantation is a safe, effective, and predictable solution for myopia. We found that the short-term visual function of patients was improved significantly. The Binoptometer 4P is an effective and convenient visual testing device for assessing postoperative visual function after ICL V4c implantation.

Для цитирования: Bai Zongxia, Nie Danyao, Zhang Jing, Hu Huiling, Sun Liangnan, Zeng Kun, Wang Jiantao, Liu Xinhua. Visual function assessment of posterior-chamber phakic implantable collamer lenses with a central port.. Annals of translational medicine. 2022. DOI: 10.21037/atm-22-107.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.