DOI 10.1097/iae.0000000000003333
MACULAR SENSITIVITY AND CAPILLARY PERFUSION IN HIGHLY MYOPIC EYES WITH MYOPIC MACULAR DEGENERATION.
Аннотация
PURPOSE: To evaluate the interrelationship between macular sensitivity and retinal perfusion density (PD) in eyes with myopic macular degeneration (MMD).
METHODS
One hundred and thirty-eight highly myopic eyes from 82 adult participants were recruited. Macular sensitivity was evaluated using the Microperimeter MP-3. Retinal PD was measured using the PLEX Elite 9000 swept source optical coherence tomography angiography. Macular sensitivity values between different categories of MMD and its relationship with optical coherence tomography angiography measurements were evaluated using multivariable linear mixed models, adjusting for age and axial length.
RESULTS
Macular sensitivity reduced with increasing severity of MMD (β ≤ -0.95, P < 0.001), whereas the best-corrected visual acuity was not associated with MMD severity (P > 0.04). Persons who were older (β = -0.08, P < 0.001), with longer axial length (β = -0.32, P = 0.005), presence of macular diffuse choroidal atrophy (β = -2.16, P < 0.001) or worse MMD (β = -5.70, P < 0.001), and presence of macular posterior staphyloma (β ≤ -2.98, P < 0.001) or Fuchs spot (β = -1.58, P = 0.04) were associated with reduced macular sensitivity. Macular sensitivity was significantly associated with deep retinal PD in MMD (β = 0.15, P = 0.004) but not with superficial retinal PD (P = 0.62).
CONCLUSION
There was a strong correlation between reduced macular sensitivity and increasing MMD severity, even in mild MMD independent of the best-corrected visual acuity. Furthermore, macular sensitivity was correlated with deep retinal PD, suggesting a vasculature-function relationship in MMD.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.