MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-018-2136-8

Медицинская библиотека · Neuroradiology · 2018

Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz.

Nishii Tatsuya, Kotoku Akiyuki, Hori Yoshiro, Matsuzaki Yuji, Watanabe Yoshiaki, Morita Yoshiaki, Kono Atsushi K, Matsuda Hitoshi, Fukuda Tetsuya

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The reliability of assessment of the artery of Adamkiewicz before the aortic repair is highly dependent on the display of the continuity of this artery with the aorta, mainly around the vertebral pedicle, by computed tomography angiography (CTA). We hypothesized that the sharp filter kernel can improve visualization of this continuity of the vessel structure because of its edge enhancement and high-spatial resolution. This study was performed to compare the subjective and objective image quality of spinal CTA reconstructed with sharp and smooth filter kernels.

METHODS

We retrospectively reviewed 40 consecutive patients who had undergone 80-kV CTA to detect the artery of Adamkiewicz before aortic repair. We measured the CT number and the contrast-to-noise ratio of the anterior spinal artery to the spinal cord. Furthermore, the continuity of the artery of Adamkiewicz was evaluated using a 3-point scale (2 points, absolute; 0 points, undetectable).

RESULTS

CTA with the sharp filter kernel showed a significantly higher CT number and contrast-to-noise ratio of the spinal artery than did CTA with the smooth filter kernel (P < .001 for both). Moreover, the sharp filter kernel showed a significantly higher continuity of the artery of Adamkiewicz with the aorta than did the smooth filter kernel (P < .001).

CONCLUSIONS

The sharp filter kernel significantly improved the image quality in low-tube-voltage CTA for the assessment of the artery of Adamkiewicz. Thus, CTA with the sharp filter kernel can generate a high-confidence level in the evaluation of the artery of Adamkiewicz.

Для цитирования: Nishii Tatsuya, Kotoku Akiyuki, Hori Yoshiro, Matsuzaki Yuji, Watanabe Yoshiaki, Morita Yoshiaki, Kono Atsushi K, Matsuda Hitoshi, Fukuda Tetsuya. Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz.. Neuroradiology. 2018. DOI: 10.1007/s00234-018-2136-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.