MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000002088

Медицинская библиотека · Nuclear medicine communications · 2025

Structured hydration accelerates I-131 clearance, reduces bladder dose, and enables earlier discharge.

Han Jinfen, Liu Manli, Wu Guihong, Zhou Miaoli, Xiong Jinmei, Liao Lijiao

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

The optimal hydration strategy to enhance radioactive iodine (I-131) clearance without compromising therapeutic efficacy remains undefined. This study aimed to evaluate whether a structured high-hydration regimen accelerates I-131 clearance, reduces radiation exposure to nontarget organs, and shortens isolation time.

METHODS

In this prospective cohort study, 456 women with papillary thyroid carcinoma receiving I-131 therapy were assigned to a high-hydration group ( ∼ 2500 ml/day) or a low-hydration group ( ∼ 1900 ml/day). Key measures included I-131 effective half-life (T_eff), time to hospital discharge, bladder cumulative dose, residual tumor uptake, and short-term reproductive outcomes.

RESULTS

The high-hydration group demonstrated a significantly shorter T_eff (22.4 ± 6.2 vs. 28.0 ± 7.3 h; P  < 0.001), earlier discharge (median 2.0 vs. 3.0 days; P  < 0.001), and a lower bladder cumulative dose (18.5 ± 5.7 vs. 22.1 ± 6.9 mGy; P  < 0.001). Tumor uptake remained comparable between groups ( P  = 0.552). No significant differences were observed in 12-month reproductive outcomes. The benefits were more pronounced in obese patients ( P -interaction = 0.02-0.04).

CONCLUSION

A structured high-hydration regimen significantly accelerates I-131 clearance, reduces bladder radiation exposure, and facilitates earlier discharge without impairing therapeutic efficacy or short-term reproductive safety. These findings support the implementation of tailored hydration protocols, particularly for obese patients, to minimize radiation exposure and optimize posttherapy management.

Для цитирования: Han Jinfen, Liu Manli, Wu Guihong, Zhou Miaoli, Xiong Jinmei, Liao Lijiao. Structured hydration accelerates I-131 clearance, reduces bladder dose, and enables earlier discharge.. Nuclear medicine communications. 2025. DOI: 10.1097/mnm.0000000000002088.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.