MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1475-1313.2008.00632.x

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2009

Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfaces.

Mas David, Espinosa Julian, Domenech Begoña, Perez Jorge, Kasprzak Henryk, Illueca Carlos

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A knowledge of the shape of the cornea is of major importance for the planning and monitoring of surgery, and for the correct diagnosis of corneal diseases. Many authors have studied the geometry of the second corneal surface in the central region and it has been stated that there is a high correlation between the central radii of curvature and asphericities of the two corneal surfaces. In this work we extend this study to a larger, central, 6 mm diameter of the cornea. Surface height data, obtained with an Oculus Pentacam from 42 eyes of 21 subjects, were analysed to yield surface power vectors. Corneal heights of both surfaces were also decomposed into low-order Zernike polynomials and the correlations between each of the power vectors and low-order Zernike coefficients for the two surfaces were studied. There was not only a strong correlation between spherical powers and Zernike defocus coefficients, but also between the astigmatic components. The correspondence between the astigmatism in both surfaces found here can be of the utmost importance in planning optical surgery, since perfect spherical ablation of the first surface does not assure total correction of corneal astigmatism.

Для цитирования: Mas David, Espinosa Julian, Domenech Begoña, Perez Jorge, Kasprzak Henryk, Illueca Carlos. Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfaces.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2009. DOI: 10.1111/j.1475-1313.2008.00632.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.