PURPOSE: To prospectively compare laser in situ keratomileusis (LASIK) flaps created with a femtosecond laser or a mechanical microkeratome and analyze the effect of the postoperative measurement interval on estimated femtosecond flap thickness using ultrasound (US) pachymetry.

SETTING

Department of Ophthalmology, University Hospital of Coimbra, and Coimbra Surgical Centre, Coimbra, Portugal.

METHODS

Flaps were created with a Hansatome Zero Compression microkeratome (Group 1), Zyoptix XP keratome (Group 2), or IntraLase 60 kHz femtosecond laser (Groups 3 and 4). Flap thickness was determined by intraoperative US pachymetry immediately after flap creation in Groups 1, 2, and 3. In Group 4, pachymetry was performed 20 minutes after the laser treatment. The main outcome measures were flap thickness and deviation from the target value.

RESULTS

Eighty patients had LASIK for myopia or myopic astigmatism. The mean flap thickness was 149.1 microm +/- 24.9 (SD) in Group 1, 124.7 +/- 23.8 microm in Group 2, 143.1 +/- 18.4 microm in Group 3, and 115.5 +/- 12.5 microm in Group 4. The difference in flap thickness between Group 3 and Group 4 was statistically significant (P<.01). The flap thickness deviation from the target value was 22.8 microm in Group 1, 19.0 microm in Group 2, 26.1 microm in Group 3, and 10.4 microm in Group 4.

CONCLUSIONS

Results indicate that the time of measurement after femtosecond affects the estimated flap thickness. Waiting 20 minutes after laser treatment permitted easier separation and may eliminate the effect of variable corneal dehydration on flap measurement by subtraction pachymetry.

Для цитирования: Rosa Andreia Martins, Neto Murta Joaquim, Quadrado Maria João, Tavares Cristina, Lobo Conceição, Van Velze Robert, Castanheira-Dinis António. Femtosecond laser versus mechanical microkeratomes for flap creation in laser in situ keratomileusis and effect of postoperative measurement interval on estimated femtosecond flap thickness.. Journal of cataract and refractive surgery. 2009. DOI: 10.1016/j.jcrs.2008.12.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.