MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0004-27492008000700008

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2008

[Evaluation of optical performance of soft contact lenses in myopic correction].

Dalcoll Marcelo Weslley, Alves Mílton Ruiz, Barreto Jackson, Yamane Iris de Souza, Bechara Samir, Mukai Adriana

Аннотация на английскомСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the optical performance of eyes fitted with two different soft contact lenses: Acuvue 2 (Vistacon J&J Vision Care Inc., USA) and World Vision Disposable Asférica Wave Front (World Vision Ophthalmic, Brazil).

METHODS

An interventional prospective clinical trial studied a sample of 40 myopic patients (-0.75D to -4.50D, with or without astigmatism up to -0.75D). Each patient had one eye randomized to visual performance evaluation including high and low contrast visual acuities, wavefront analysis and contrast sensitivity.

RESULTS

The Nidek OPD Scan detected a residual refraction (hypercorrection) for both contact lenses. High contrast visual acuity was significantly higher for World Vision soft contact lenses. Low contrast visual acuity was similar for both soft contact lenses. Contrast sensitivity improved significantly at 1.5; 3; 6 e 18 spatial frequencies for both soft contact lenses, but no difference was found between them. Regarding wavefront analysis, no difference was found between both soft contact lenses. There were not significantly differences in the Strehl indices and MTF for both soft contact lenses.

CONCLUSION

World Vision Disposable Asférica Wave Front soft contact lenses had a better performance regarding high contrast visual acuity. However, low contrast visual acuity, wavefront analysis and contrast sensitivity were similar for both soft contact lenses.

Для цитирования: Dalcoll Marcelo Weslley, Alves Mílton Ruiz, Barreto Jackson, Yamane Iris de Souza, Bechara Samir, Mukai Adriana. [Evaluation of optical performance of soft contact lenses in myopic correction].. Arquivos brasileiros de oftalmologia. 2008. DOI: 10.1590/s0004-27492008000700008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.