Intravenous cibenzoline in the management of acute supraventricular tachyarrhythmias.

Bru P, Cointe R, Paganelli F, Ricard P, Lévy S

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Intravenous cibenzoline was evaluated in 37 patients with acute supraventricular tachyarrhythmias and a ventricular rate > 120 beats/min. The presenting arrhythmia was atrial fibrillation in 15 patients, atrial flutter in 5, ectopic atrial tachycardia in 11, and paroxysmal atrioventricular (AV) junctional reentrant tachycardia in 6 patients. Intravenous cibenzoline was administered as a bolus given over 2 minutes, at a dose of 1 mg/kg in the first 26 patients and 1.2 mg/kg in the subsequent 11 patients, 15 minutes following failure of placebo (isotonic glucose). The results were evaluated 15 minutes after the intravenous injection. Restoration of sinus rhythm was obtained in 3 out of 6 patients with paroxysmal AV junctional tachycardia (50%) and in 7 out of 31 patients (23%) with atrial tachyarrhythmias (5 out of 15 patients with atrial fibrillation and 2 out of 16 patients with ectopic atrial tachycardia or atrial flutter). Five additional patients with atrial tachyarrhythmias had slowing of ventricular rate below 100 beats/min. Therefore, a satisfactory result, that is, restoration of sinus rhythm or slowing of ventricular rate, occurred in 15 patients (40.5%). Side effects were transient, including visual disturbance (one patient), asymptomatic widening of QRS complex (three patients), incessant reciprocating tachycardia (one patient), and acceleration of ventricular rate (eight patients), resulting in 1:1 flutter, with poor tolerance in two patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Bru P, Cointe R, Paganelli F, Ricard P, Lévy S. Intravenous cibenzoline in the management of acute supraventricular tachyarrhythmias.. Cardiovascular drugs and therapy. 1995. DOI: 10.1007/bf00877748.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.