Accessory pathway and atrioventricular node reentrant tachycardia in elderly patients: clinical features, electrophysiologic characteristics and results of radiofrequency ablation.

Chen S A, Chiang C E, Yang C J, Cheng C C, Wu T J, Wang S P, Chiang B N, Chang M S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study was designed to evaluate the clinical features, electrophysiologic characteristics and results of radiofrequency ablation in elderly patients with accessory atrioventricular (AV) pathways or AV node reentrant tachycardia.

BACKGROUND

Radiofrequency ablation in elderly patients with paroxysmal supraventricular tachycardia has not been well described, and comparative study between elderly and younger patients is limited.

METHODS

Electrophysiologic studies and radiofrequency ablation were performed in 92 elderly patients (45 with an accessory pathway, 47 with AV node reentrant tachycardia).

RESULTS

The elderly patients had poorer electrophysiologic properties in accessory pathways and dual AV node pathways than those of younger patients. The success rate of radiofrequency ablation was similar in elderly and younger patients. However, elderly patients had more complications (14%) in left-sided accessory pathways.

CONCLUSIONS

Radiofrequency ablation in elderly patients with supraventricular tachycardia was effective. However, it must be performed cautiously in those patients with left-sided accessory pathways.

Для цитирования: Chen S A, Chiang C E, Yang C J, Cheng C C, Wu T J, Wang S P, Chiang B N, Chang M S. Accessory pathway and atrioventricular node reentrant tachycardia in elderly patients: clinical features, electrophysiologic characteristics and results of radiofrequency ablation.. Journal of the American College of Cardiology. 1994. DOI: 10.1016/0735-1097(94)90757-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.