DOI 10.1590/s0004-27492008000500008

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2008

[Refractional results of LASIK retreatment with wavefront-guided ablation versus standard ablation].

Urbano Andréia Peltier, Nosé Walton

Сравнительное исследованиеАннотация на английскомСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate refractive outcomes of wavefront-guided LASIK (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb) in retreatment of primary LASIK for myopia and myopic astigmatism.

METHODS

A prospective, randomized trial with paired eye control of 74 eyes from 37 patients who underwent LASIK retreatment was performed. Each patient underwent retreatment using Zyoptix LASIK in 1 eye and Planoscan LASIK in the contralateral eye. A complete ophthalmologic examination was performed, including evaluation of high contrast visual acuity and manifest refraction, with a follow-up of 6 months.

RESULTS

Both Zyoptix and Planoscan groups had similar values of high contrast visual acuity, gain and loss of best spectacle-corrected visual acuity, safety and efficacy indexes, percentage of eyes with spherical equivalent within +/- 0,50 D and +/- 1,00 D in the postoperative period of 6 months. In the Zyoptix group, the values of spherical component and spherical equivalent of manifest refraction were more hyperopic than in the Planoscan group in the postoperative periods of 1 week, 1, 3 and 6 months. The predictability of spherical equivalent correction was better for the Zyoptix group than for the Planoscan group at 6 months.

CONCLUSIONS

Wavefront-guided LASIK with Zyoptix produces superior refractive outcomes than standard LASIK with Planoscan in retreatment of refractive errors after primary LASIK. High contrast visual acuity measures are not sensitive in showing the best technique.

Для цитирования: Urbano Andréia Peltier, Nosé Walton. [Refractional results of LASIK retreatment with wavefront-guided ablation versus standard ablation].. Arquivos brasileiros de oftalmologia. 2008. DOI: 10.1590/s0004-27492008000500008.