MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20081001-13

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2008

Subconjunctival gas bubble Formation during LASIK flap creation using femtosecond laser.

Ide Takeshi, Kymionis George D, Goldman David A, Yoo Sonia H, O'Brien Terrence P

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report a patient who developed subconjunctival gas bubble formation during creation of a LASIK corneal flap with the IntraLase femtosecond laser.

METHODS

Case report of a 19-year-old-man with compound myopic astigmatism and a normal preoperative evaluation who underwent bilateral simultaneous LASIK.

RESULTS

The IntraLase FS15 was used to create an 8.8-mm diameter superior flap. Laser settings were 110-microm depth, 1.70-mJ bed and side-cut energy, 12-microm spot separation, 10-microm line separation, 70 degrees side-cut angle, 240-microm pocket start width, and 200-microm pocket start depth. The procedure was uneventful in the right eye whereas subconjunctival air bubbles were observed along the corneal limbus in the left eye (no bubbles were seen in the peripheral cornea). The patient was examined 30 minutes later, and the subconjunctival bubbles could still be observed. By the next day, the bubbles had disappeared completely. Postoperative uncorrected visual acuity was 20/20 in both eyes.

CONCLUSIONS

Subconjuctival bubbles can be found after LASIK flap creation with a femtosecond laser.

Для цитирования: Ide Takeshi, Kymionis George D, Goldman David A, Yoo Sonia H, O'Brien Terrence P. Subconjunctival gas bubble Formation during LASIK flap creation using femtosecond laser.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2008. DOI: 10.3928/1081597x-20081001-13.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.