Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2013

The time course of exit and entrance block during cryoballoon pulmonary vein isolation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Andrade Jason, Khairy Paul, Dubuc Marc, Deyell Marc W, Roy Denis, Talajic Mario, Thibault Bernard, Guerra Peter G, Rivard Léna, Macle Laurent

Аннотация

AIMS: The dynamic time course of entrance and exit block during pulmonary vein isolation (PVI) is unknown. The purpose of this series was to dynamically evaluate the manifestation of entrance and exit conduction block during simultaneous circumferential PVI.

METHODS AND RESULTS: Pacing manoeuvres were performed during cryoballoon ablation of left-sided pulmonary veins (PVs) in 30 consecutive patients with a history of drug-refractory paroxysmal atrial fibrillation. At the onset of ablation continuous pacing was performed from the PV at a cycle length of 600 ms until the appearance of exit block. Once exit block was demonstrated, uninterrupted pacing was immediately transitioned to the distal coronary sinus (CS) catheter and continued at 600 ms throughout the rest of the cryoapplication. The timing of exit block, entrance block, and corresponding cryoballoon temperature were noted for all patients. In the 45 PVs when real-time PV recordings were available during cryothermal ablation, the presence of exit block was reliably demonstrated to precede entrance block (P < 0.0001) by a median of 5 s [interquartile range (IQR) 3, 12; median temperature at isolation -39°C (IQR -30, -45); nadir ablation temperature -53°C (IQR -48, -59)]. In all cases, when uninterrupted pacing was transitioned from the PV to the distal CS, entrance conduction from the left atrium to PV remained intact.

CONCLUSION: Circumferential PV ablation results in progressive PVI, beginning with unidirectional exit block, and followed by entrance block. As exit block reliably precedes entrance block, we are able to provide justification for the exclusive use of entrance conduction block as the endpoint of cryoballoon-based PVI.