MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12015

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2012

Reduction of procedure duration and radiation exposure with a dedicated inner lumen mapping catheter during pulmonary vein cryoablation.

Peyrol Michaël, Sbragia Pascal, Quatre Amandine, Orabona Morgane, Casalta Anne-Claire, Boccara Gilles, Zerrouk Zinedine, Guenoun Maxime, Lévy Samuel, Paganelli Franck

Контролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Achieve catheter (AC; Medtronic-CryoCath, Pointe-Claire, Canada) is a circular mapping catheter introduced through the lumen of the cryoballoon (CB) catheter which is safe and effective to both navigate the CB to the pulmonary veins (PV) and allow PV potential recording during PV cryoablation. The aim of this study was to evaluate the impact of the use of the AC on procedural outcomes.

METHODS

Sixteen consecutive patients (14 men) underwent AC-guided PV isolation (PVI) for drug-refractory paroxysmal atrial fibrillation (AF; AC group). Clinical and procedural data of these patients were compared to those obtained from 16 consecutive patients who had undergone PVI for paroxysmal AF with the regular "single transseptal" approach (control group).

RESULTS

Clinical characteristics of patients enrolled in both groups did not differ significantly. In the AC group, 64 PVs were targeted using a single 28-mm (n = 13) or 23-mm (n = 3) CB catheter with PVI achieved in 62 PVs (97%). In the control group, 66 PVs were targeted using a single 28-mm (n = 12) or 23-mm (n = 4) CB catheter with PVI achieved in 62 PVs (94%), (P = non-significant for CB size and PVI rate). Procedure duration and fluoroscopy time were significantly reduced in AC group compared to control group (96.6 ± 26 minutes vs 125.9 ± 25 minutes, P = 0.003 and 24.4 ± 10 minutes vs 32.6 ± 11 minutes, P = 0.04, respectively).

CONCLUSION

The use of the AC significantly reduced procedure duration and radiation exposure during PVI with the CB technique.

Для цитирования: Peyrol Michaël, Sbragia Pascal, Quatre Amandine, Orabona Morgane, Casalta Anne-Claire, Boccara Gilles, Zerrouk Zinedine, Guenoun Maxime, Lévy Samuel, Paganelli Franck. Reduction of procedure duration and radiation exposure with a dedicated inner lumen mapping catheter during pulmonary vein cryoablation.. Pacing and clinical electrophysiology : PACE. 2012. DOI: 10.1111/pace.12015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.