New methods for quantifying diplopia.

Holmes Jonathan M, Leske David A, Kupersmith Mark J

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To develop new methods for quantifying diplopia and test their validity, test-retest reliability, and responsiveness to treatment.

DESIGN

Prospective case series.

PARTICIPANTS

Adult patients with diplopia in 2 tertiary referral practices. Diagnosis included cranial nerve palsies, thyroid eye disease, supranuclear palsies, and ocular myasthenia gravis.

METHODS

The new diplopia questionnaire and cervical range of motion (CROM) diplopia examination were tested in a 15-patient validity study against the standard diplopia field performed on the Goldmann perimeter (each scored 0 [no diplopia] to 100 [constant diplopia in all fields]). The test-retest reliability of the CROM diplopia examination was determined in 27 patients. The responsiveness to treatment of the diplopia questionnaire and the CROM examination was tested in 15 patients who underwent strabismus surgery or received systemic prednisone for ocular myasthenia gravis.

MAIN OUTCOME MEASURES: Validity was evaluated by the intraclass correlation coefficient (ICC) compared with the standard Goldmann diplopia field. Test-rest reliability was evaluated by the ICC. Responsiveness to treatment was evaluated by comparing pretreatment and posttreatment scores.

RESULTS

There was excellent agreement between the diplopia questionnaire score and Goldmann diplopia field score (ICC, 0.90) and between the CROM diplopia examination score and Goldmann diplopia field score (ICC, 0.88). Intertester reliability of the CROM diplopia examination score was excellent (ICC, 0.87; 95% confidence interval, 0.74-0.94). Postintervention scores were significantly lower than baseline (P = 0.0003 for CROM and P = 0.0001 for the questionnaire), with a median postintervention improvement of 48 for the CROM diplopia score (quartiles 12-68) and 36 for the diplopia questionnaire (quartiles 20-52).

CONCLUSIONS

Our new diplopia questionnaire and new CROM diplopia examination are valid, reliable, and responsive measures of diplopia severity. The tests are easy to administer and require less expensive and less cumbersome equipment than previously available.

Для цитирования: Holmes Jonathan M, Leske David A, Kupersmith Mark J. New methods for quantifying diplopia.. Ophthalmology. 2005. DOI: 10.1016/j.ophtha.2005.06.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.