Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2012
High-rate pacing-induced atrial fibrillation effectively reveals properties of spontaneously occurring paroxysmal atrial fibrillation in humans.
Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Calvo David, Atienza Felipe, Jalife José, Martínez-Alzamora Nieves, Bravo Loreto, Almendral Jesús, González-Torrecilla Esteban, Arenal Ángel, Bermejo Javier, Fernández-Avilés Francisco, Berenfeld Omer
Аннотация
AIMS: Research on paroxysmal atrial fibrillation (AF) assumes that fibrillation induced by rapid pacing adequately reproduces spontaneously occurring paroxysmal AF in humans. We aimed to compare the spectral properties of spontaneous vs. induced AF episodes in paroxysmal AF patients.
METHODS AND RESULTS: Eighty-five paroxysmal AF patients arriving in sinus rhythm to the electrophysiology laboratory were evaluated prior to ablation. Atrial fibrillation was induced by rapid pacing from the pulmonary vein-left atrial junctions (PV-LAJ), the coronary sinus (CS), or the high right atrium (HRA). Simultaneous recordings were obtained using multipolar catheters. Off-line power spectral analysis of 5 s bipolar electrograms was used to determine dominant frequency (DF) at recording sites with regularity index >0.2. Sixty-eight episodes were analysed for DF. Comparisons were made between spontaneous (n = 23) and induced (n = 45) AF episodes at each recording site. No significant differences were observed between spontaneous and induced AF episodes in HRA (5.18 ± 0.69 vs. 5.06 ± 0.91 Hz; P = 0.64), CS (5.27 ± 0.69 vs. 5.36 ± 0.76 Hz; P = 0.69), or LA (5.72 ± 0.88 vs. 5.64 ± 0.75 Hz; P = 0.7) regardless of pacing site. Consistent with these results, paired analysis in seven patients with both spontaneous and induced AF episodes, showed no regional DFs differences. Moreover, a left-to-right DF gradient was also present in both spontaneous (PV-LAJ 5.71 ± 0.81 vs. HRA 5.18 ± 0.69 Hz; P = 0.005) and induced (PV-LAJ 5.62 ± 0.72 vs. HRA 5.07 ± 0.91 Hz; P = 0.002) AF episodes, with no differences between them (P = not specific).
CONCLUSION: In patients with paroxysmal AF, high-rate pacing-induced AF adequately mimics spontaneously initiated AF, regardless of induction site.
METHODS AND RESULTS: Eighty-five paroxysmal AF patients arriving in sinus rhythm to the electrophysiology laboratory were evaluated prior to ablation. Atrial fibrillation was induced by rapid pacing from the pulmonary vein-left atrial junctions (PV-LAJ), the coronary sinus (CS), or the high right atrium (HRA). Simultaneous recordings were obtained using multipolar catheters. Off-line power spectral analysis of 5 s bipolar electrograms was used to determine dominant frequency (DF) at recording sites with regularity index >0.2. Sixty-eight episodes were analysed for DF. Comparisons were made between spontaneous (n = 23) and induced (n = 45) AF episodes at each recording site. No significant differences were observed between spontaneous and induced AF episodes in HRA (5.18 ± 0.69 vs. 5.06 ± 0.91 Hz; P = 0.64), CS (5.27 ± 0.69 vs. 5.36 ± 0.76 Hz; P = 0.69), or LA (5.72 ± 0.88 vs. 5.64 ± 0.75 Hz; P = 0.7) regardless of pacing site. Consistent with these results, paired analysis in seven patients with both spontaneous and induced AF episodes, showed no regional DFs differences. Moreover, a left-to-right DF gradient was also present in both spontaneous (PV-LAJ 5.71 ± 0.81 vs. HRA 5.18 ± 0.69 Hz; P = 0.005) and induced (PV-LAJ 5.62 ± 0.72 vs. HRA 5.07 ± 0.91 Hz; P = 0.002) AF episodes, with no differences between them (P = not specific).
CONCLUSION: In patients with paroxysmal AF, high-rate pacing-induced AF adequately mimics spontaneously initiated AF, regardless of induction site.
Предметные рубрики MeSH
Action PotentialsAdultAtrial FibrillationCardiac Pacing, ArtificialChi-Square DistributionCoronary SinusElectrophysiologic Techniques, CardiacFemaleHeart AtriaHeart Conduction SystemHumansLogistic ModelsMaleMiddle AgedOdds RatioPredictive Value of TestsPulmonary VeinsSignal Processing, Computer-AssistedTime FactorsVoltage-Sensitive Dye Imaging