DOI 10.1016/j.jacep.2021.09.015

Медицинская библиотека · JACC. Clinical electrophysiology · 2021

Temporal Association of Atrial Fibrillation With Cardiac Implanted Electronic Device Detected Heart Failure Status.

Capucci Alessandro, Wong Jorge A, Gold Michael R, Boehmer John, Ahmed Rezwan, Kwan Brian, Thakur Pramodsingh H, Zhang Yi, Jones Paul W, Healey Jeffrey S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to investigate the temporal association between changes in physiologic heart failure (HF) sensors, atrial fibrillation (AF) progression, and clinical HF in patients with cardiac resynchronization therapy implantable defibrillators (CRT-D) designed to monitor AF and HF daily.

BACKGROUND

AF is a common comorbidity in HF; however, it is unclear if HF triggers AF, or vice-versa. Current implantable cardiac devices have sensors capable of quantifying HF status, which permits a greater understanding of the impact of AF on HF status and may help guide treatment.

METHODS

The MultiSENSE (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients) study collected multiple sensor data indicative of HF status in patients with CRT-D followed for up to 12 months. Patients were grouped according to their longest daily AF burden: 1) at least 24 hours of AF (HIGH AF); 2) between 6 minutes and 24 hours (MID AF); and 3) <6 minutes (NO AF). Sensor data were aligned to the first qualifying AF event or a randomly selected day for patients in the NO AF group.

RESULTS

Among 869 patients with daily AF data available, 98 patients had HIGH AF, 141 patients MID AF, and 630 patients NO AF. At baseline, history of AF, N-terminal pro hormone B-type natriuretic peptide and device-measured S3 were associated with development of AF. HeartLogic index increased before AF onset (Δ HeartLogic = 9.83 ± 2.49; P < 0.001). Multivariable time-dependent Cox regression showed an increased risk for HF events following a 24-hour AF episode compared with no 24-hour AF (hazard ratio: 1.96; 95% confidence interval: 1.03-3.74).

CONCLUSIONS

Device-measured HF indicators worsened before AF onset, whereas clinical HF deterioration only became apparent after AF occurred. Thus, the sensitivity of methods to ascertain AF and HF status appear to influence the direction of perceived causality. (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients [MultiSENSE]; NCT01128166).

Для цитирования: Capucci Alessandro, Wong Jorge A, Gold Michael R, Boehmer John, Ahmed Rezwan, Kwan Brian, Thakur Pramodsingh H, Zhang Yi, Jones Paul W, Healey Jeffrey S. Temporal Association of Atrial Fibrillation With Cardiac Implanted Electronic Device Detected Heart Failure Status.. JACC. Clinical electrophysiology. 2021. DOI: 10.1016/j.jacep.2021.09.015.