The American journal of cardiology · 2022

Low Blood Pressure Threshold for Adverse Outcomes During Left Ventricular Assist Device Support.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vidula Himabindu, Altintas Onur, McNitt Scott, DeVore Adam D, Birati Edo Y, Genuardi Michael V, Sheikh Farooq H, Polonsky Bronislava, Alexis Jeffrey D, Gosev Igor, Bisognano John D, Kutyifa Valentina, Seidmann Abraham, Goldenberg Ilan

Аннотация

It has been suggested that maintaining low mean arterial pressure (MAP) in left ventricular assist device (LVAD) recipients is associated with a reduced risk of stroke/death. However, the lower limit of the optimal MAP range has not been established. We aimed to identify this lower limit in a contemporary cohort of LVAD recipients with frequent longitudinal MAP measurements. We analyzed 86,651 MAP measurements in 309 patients with an LVAD (32% LVADs with full magnetic levitation of the impeller) at a tertiary medical center during a mean follow-up of 1.7 ± 1.1 years. Cox proportional hazards regression modeling was used to study the association of serial MAP measurements with stroke/death within 3 years after index discharge. Multivariate analysis identified MAP ≤75 mm Hg, compared with MAP >75 mm Hg, as the low MAP threshold associated with increased risk of death (hazard ratio [HR] 4.74, 95% confidence interval [CI] 2.85 to 7.87, p <0.001), stroke (HR 2.72;, 95% CI 1.39 to 5.33, p = 0.01), and stroke/death (HR 4.45, 95% CI 2.83 to 6.99, p <0.001). The risk associated with MAP ≤75 mm Hg was consistent in subgroups categorized by age, gender, race, device type, renal function, right-sided heart failure, and blood pressure medications. In conclusion, our findings suggest that maintaining MAP ≤75 mm Hg during long-term follow-up in LVAD recipients is associated with increased risk of stroke/death regardless of risk factors or medical management.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты