MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a0543

Медицинская библиотека · AJNR. American journal of neuroradiology · 2007

Carotid stenting without use of balloon angioplasty and distal protection devices: preliminary experience in 100 cases.

Maynar M, Baldi S, Rostagno R, Zander T, Rabellino M, Llorens R, Alvarez J, Barajas F

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: A major concern during carotid artery stent placement is the potential for cerebral embolism. Diminishing the number of device manipulations across the lesion might reduce procedural stroke risk. For this purpose, we report our initial experience with carotid stent placement without the use of either balloon angioplasty or distal protection devices.

MATERIALS AND

METHODS

Eighty-seven consecutive patients with 100 carotid stenoses compose this series. Ninety four of the 100 hundred stented carotid arteries were either symptomatic (58 [58%]) or had a greater than 70% stenosis (36 [36%]). Six percent of them were asymptomatic and had stenosis between 50% and 70%. Patients underwent neurologic evaluation before the procedure and during follow-up at 1, 3, 6, and 12 months and annually thereafter. Carotid sonography and plain films of the neck were performed immediately after the procedure and then at the same time intervals.

RESULTS

Primary stent placement was successful in 98 of 100 case subjects. In 2 case subjects, predilation was necessary before stent deployment. Neurologic periprocedural complications included 1 nondisabling and 1 disabling stroke and 5 transient ischemic attacks. The mean duration of follow-up was 23 months (range: 10-36 months). During the follow-up period, there were 5 deaths, all unrelated to the carotid disease, and no major stroke. The degree of stenosis decreased from a mean of 78.85% before the procedure to a mean of 21.23% immediately after.

CONCLUSIONS

In this series, carotid stent placement without the use of either balloon angioplasty or distal protection devices was safe and effective with a low incidence of periprocedural complications.

Для цитирования: Maynar M, Baldi S, Rostagno R, Zander T, Rabellino M, Llorens R, Alvarez J, Barajas F. Carotid stenting without use of balloon angioplasty and distal protection devices: preliminary experience in 100 cases.. AJNR. American journal of neuroradiology. 2007. DOI: 10.3174/ajnr.a0543.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.