Carotid stent delivery in an XMR suite: immediate assessment of the physiologic impact of extracranial revascularization.

Martin Alastair J, Saloner David A, Roberts Timothy P L, Roberts Heidi, Weber Oliver M, Dillon William, Cullen Sean, Halbach Van, Dowd Christopher F, Higashida Randall T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Patients undergoing stent placement as treatment for severe stenosis of the internal carotid artery (ICA) were assessed with MR imaging in a combined MR-radiographic (XMR) angiography suite. MR imaging was performed before and immediately following conventional radiography-guided stent placement. Changes in MR imaging measurable properties, including flow and perfusion, resulting from stent placement were evaluated.

PATIENTS AND TECHNIQUES: MR imaging analysis was performed for 12 patients with >70% stenosis of the ICA before and after conventional radiography-guided deployment of a carotid stent. MR imaging acquisitions included angiography, quantitative flow analysis, perfusion, diffusion, and turbo-fluid-attenuated inversion recovery (FLAIR). These acquisitions were all performed immediately before and following stent placement by using conventional techniques.

RESULTS

MR angiography proved sufficient for identifying the target lesion and permitting targeted flow analysis. MR flow analysis demonstrated a marked increase in flow in the treated carotid artery (+2.2 +/- 1.2 mL/s) and little change in other extracranial arteries. MR perfusion imaging showed no significant differences in relative cerebral blood volume between hemispheres before or after treatment, but there was a modest decrease in mean transit time and time to peak evident in the treated hemisphere after stent placement. Diffusion imaging did not demonstrate any ischemic foci resulting from carotid stent treatment. Hyperintensity of the CSF was noted on turbo-FLAIR acquisitions in the ipsilateral hemisphere following stent placement in 75% of patients.

CONCLUSION

MR imaging reliably reflects the state of the carotid artery and provides a means of monitoring and quantifying the effects of revascularization.

Для цитирования: Martin Alastair J, Saloner David A, Roberts Timothy P L, Roberts Heidi, Weber Oliver M, Dillon William, Cullen Sean, Halbach Van, Dowd Christopher F, Higashida Randall T. Carotid stent delivery in an XMR suite: immediate assessment of the physiologic impact of extracranial revascularization.. AJNR. American journal of neuroradiology. 2005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.