Journal of medical imaging (Bellingham, Wash.) · 2025

Application of thin-slice and accelerated T1-weighted GRE sequences in 1.5T abdominal magnetic resonance imaging using deep learning image reconstruction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Joos Natalie S, Afat Saif, Nickel Marcel Dominik, Weiland Elisabeth, Herrmann Judith, Ursprung Stephan, Almansour Haidara, Lingg Andreas, Werner Sebastian, Haase Bianca, Nikolaou Konstantin, Gassenmaier Sebastian

Аннотация

PURPOSE: Deep-learning (DL)-based image reconstruction (DLR) is a key technique for reducing acquisition time (TA) and increasing morphologic resolution in abdominal magnetic resonance imaging (MRI). We aim to compare the performance of a standard ( VIBE Std ) gradient echo (GRE) sequence with Dixon fat separation versus an accelerated ultra-fast ( VIBE UF ) and high-resolution ( VIBE HR ) T1-weighted GRE sequence with Dixon fat separation and DLR.

APPROACH: A total of 50 patients with an abdominal 1.5T MRI, with a mean age of 59 ± 11 years, were prospectively included from January to July 2023. Each examination protocol included VIBE Std , VIBE UF , and VIBE HR . Both DL sequences use more aggressive parallel imaging and partial Fourier sampling to reduce TA (slice thickness VIBE Std and VIBE UF 3 mm, VIBE HR 2 mm). Evaluation of each contrast-enhanced datasets for noise, artifacts, sharpness/contrast, overall image quality, and diagnostic confidence was performed independently by four radiologists using a Likert scale of 1 to 5 (5 = best).

RESULTS: VIBE UF significantly reduced TA (mean 7.3 s versus 15.0 s ( VIBE Std ) and 14.5 s ( VIBE HR ); p < 0.001 ). Both DL sequences provided significantly better sharpness/contrast for all organs compared with VIBE Std (median 5 versus 4; p < 0.001 ). VIBE UF showed less noise than VIBE Std (median 5 versus 4; p < 0.001 ), but VIBE Std was less artifact-affected than both DL sequences (median 5 versus 4; p < 0.001 ). Overall image quality was superior in both DL sequences compared with VIBE Std (median 5 versus 4; p < 0.001 ). Diagnostic confidence and lesion detectability were not significantly different ( p > 0.05 ).

CONCLUSION: DL-based image reconstruction significantly improves overall image quality for VIBE UF and VIBE HR , with VIBE UF reducing TA by ∼ 50 % .