MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2024.07.012

Медицинская библиотека · The Journal of arthroplasty · 2024

Mix and Match Use of Revision Universal Head-Neck Adapters in Hip Arthroplasty: A Complications and Survival Analysis of 306 Cases.

Valentini Marisa, Thaller Alexander, Ruckenstuhl Paul, Sadoghi Patrick, Leithner Andreas, Leitner Lukas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Outcomes and safety of "mix and match" in total hip arthroplasty (THA) using universal head-neck adapters (UHNA) are a matter of ongoing discussion and concern due to legal affairs. This study aimed at analyzing the "mix and match" use of UHNA and evaluating complication and reoperation rates, possible risk factors, and the implant's survival.

METHODS

A total of 306 patients treated with THA (94.1% revisions) using a UHNA at our institution between 2006 and 2022 were identified and included. Diagnoses, comorbidities, implants, and UHNA specifications were retrospectively recorded. Outcomes, complications, and survival analyses were evaluated, taking into account various possible risk factors.

RESULTS

There were 19.9% of the 306 included cases (58.5% women; median age 74 years; median follow-up 57 months) that had at least 1 complication. There were 43 patients (14.1%) who had to receive ≥1 rerevision surgery. The most common complication was postoperative recurrent dislocation (n = 27, 8.8%). There was one case of a prosthetic stem-neck fracture that was registered. Statistically significant risk factors for postoperative recurrent dislocations and postoperative aseptic loosening were, respectively, dislocation as an indication for UHNA implantation (P < .001) and oversized neck lengths (≥2XL; P = .004). The overall revision-free survival was 92% after 1 year and 82% at ten years. Statistically significant better survival rates were registered in patients ≥60 years old, who had fewer comorbidities (<2), and normal neck lengths (S to XL).

CONCLUSIONS

The results of this study underline the overall safety of UHNA use in THA through "mix and match." Only one case of a stem-neck fracture was identified. The highlighted risk factors for failure must be kept in mind during the decision-making process with patients.

Для цитирования: Valentini Marisa, Thaller Alexander, Ruckenstuhl Paul, Sadoghi Patrick, Leithner Andreas, Leitner Lukas. Mix and Match Use of Revision Universal Head-Neck Adapters in Hip Arthroplasty: A Complications and Survival Analysis of 306 Cases.. The Journal of arthroplasty. 2024. DOI: 10.1016/j.arth.2024.07.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.