Propensity Score-matched Comparison of WEB 17 and WEB 21 with 4-7 mm Device Sizes for the Treatment of Unruptured Intracranial Aneurysms.

Goertz Lukas, Liebig Thomas, Siebert Eberhard, Zopfs David, Pennig Lenhard, Schlamann Marc, Radomi Alexandra, Dorn Franziska, Kabbasch Christoph

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The WEB 17 system represents the fifth generation of Woven Endobridge (WEB) flow disruptors and features a low profile with fewer wires than its predecessor, the WEB 21. The present study compares the safety and efficacy of the WEB 17 and WEB 21 for the treatment of unruptured cerebral aneurysms with 4-7 mm device sizes, which were available for both systems.

METHODS

Patient and aneurysm characteristics, complications, clinical outcome and angiographic results were retrospectively analysed. 1:1 propensity score matching was performed to adjust for minor baseline differences between the groups.

RESULTS

Sixty aneurysms treated with WEB 21 and 90 with WEB 17 were included. The overall failure rate (deployment failure and adjunctive stent) was significantly higher with WEB 21 (16.7%) than with WEB 17 (3.3%, p < 0.01). The rates of neurological events between WEB 21 (6.7%) and WEB 17 treatment (1.1%) were not significantly different (p = 0.08). Also, procedural morbidity was comparably low in both groups (WEB 21: 3.3%, WEB 17: 0%, p = 0.16). The rates of complete/adequate occlusion at follow up were 69.7%/86.4% for WEB 17 vs. 80.4%/91.3% for WEB 21 at short-term (p = 0.27), and 64.5%/83.9% vs. 75.9%/86.2% at mid-term (p = 0.41), respectively. Propensity score matching confirmed the results of the unmatched series.

CONCLUSION

WEB 17 and WEB 21 had a similar safety and efficacy profile, but WEB 17 was associated with an improved feasibility. Prospective studies with long-term follow-up will define the full potential of the WEB 17 system.

Для цитирования: Goertz Lukas, Liebig Thomas, Siebert Eberhard, Zopfs David, Pennig Lenhard, Schlamann Marc, Radomi Alexandra, Dorn Franziska, Kabbasch Christoph. Propensity Score-matched Comparison of WEB 17 and WEB 21 with 4-7 mm Device Sizes for the Treatment of Unruptured Intracranial Aneurysms.. Clinical neuroradiology. 2024. DOI: 10.1007/s00062-024-01430-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.