MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jeo2.70571

Медицинская библиотека · Journal of experimental orthopaedics · 2025

Evaluation of the donor site defect after harvesting the medial third of the patellar tendon in ACL reconstruction: An MRI study.

Georgoulis Jim, Savvidou Olga, Kosta Paraskevi, Patras Kostas, Argyropoulou Maria, Papagelopoulos Panayiotis, Georgoulis Anastasios

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Previous studies have reported magnetic resonance imaging (MRI) changes in the donor-site defect size following anterior cruciate ligament reconstruction (ACLR) using the middle third of the patellar tendon (mid-third patellar tendon ACLR); however, no corresponding reports exist for ACLR using the medial third of the patellar tendon (medial-third patellar tendon ACLR). This study aimed to assess the changes in donor-site defect size postoperatively in medial-third ACLR patients and hypothesized a clinically relevant MRI change within the first year.

METHODS

Twenty-two consecutive patients underwent MRI examinations to measure the donor-site defect size ('gap' signal) and laterally remaining tendon size ('normal tendon' signal) at two time points: 14 (±5) days and 7.9 (±2.0) months postoperatively. The primary outcome was the post-pre difference of the "gap" signal. Wilcoxon signed rank test assessed the post-pre difference of the 'gap' signal, while robust linear regression examined the effect of either age at surgery or follow-up time on the post-pre difference of the 'gap' signal.

RESULTS

The primary finding was a significant reduction in the 'gap' signal [-9.2 mm (95% CI: -12.3; -6.7)] between 2 weeks and ~8 months (p < 0.001). The 'normal tendon' signal did not change significantly [1.6 mm (95% CI: -0.5; 3.3), p = 0.237]. Age at surgery had a negative, statistically nonsignificant effect on donor-site 'gap' signal difference (-2.24 [95% CI: -5.59; 0.60], p = 0.106). In addition, follow-up time had a negative, statistically nonsignificant effect on donor-site 'gap' signal difference (-0.97 [95% CI: -2.98; 4.14], p = 0.571). Eight of 22 patients had no detectable 'gap' signal at 8 months.

CONCLUSION

The most important finding for this study is a significant decrease in the donor-site defect along with an undetectable 'gap' that was verified for ~36% of the sample at a minimum mean follow-up of ~8 months. The laterally remaining 'normal tendon' signal remained unchanged. Neither age at surgery nor follow-up time had an impact on the healing of the donor-site defect. From a clinical perspective our findings suggest that the medial-third patellar tendon autograft has a high healing capacity after harvesting, already at a mean follow-up of ~8 months.

LEVEL OF EVIDENCE: Level IV.

Для цитирования: Georgoulis Jim, Savvidou Olga, Kosta Paraskevi, Patras Kostas, Argyropoulou Maria, Papagelopoulos Panayiotis, Georgoulis Anastasios. Evaluation of the donor site defect after harvesting the medial third of the patellar tendon in ACL reconstruction: An MRI study.. Journal of experimental orthopaedics. 2025. DOI: 10.1002/jeo2.70571.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.