m+Medelevator.RU
← Поиск публикаций
Scandinavian journal of gastroenterology · 2025

A comparative study between ultrasound-guided-attenuation-parameter (UGAP), controlled attenuation parameter (CAP), and proton density fat fraction (PDFF) for assessment of hepatic steatosis.

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Byenfeldt Marie, Grönlund Christer, Nasr Patrik, Lindam Anna, Ekstedt Mattias, Lundberg Peter, Kihlberg Johan

Аннотация

OBJECTIVES: Gastroenterology clinics often assess hepatic steatosis using CAP-FibroScan, while radiology departments increasingly apply UGAP instead of subjective B-mode ultrasound. This study compares CAP and UGAP feasibility and diagnostic performance across steatosis stages, using PDFF as reference.

MATERIALS AND METHODS: Healthy controls and a cohort with known steatosis and fibrosis were examined between September 2022 and October 2024. Presence of steatosis (≥S1) defined as ≥5% PDFF, and presence of fibrosis was evaluated with MRE. Participants with even sex distribution were examined in supine and 30° left decubitus position; for UGAP, with normal (4 N) and (30 N) probe force. Diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUROC).

RESULTS: In the group of N = 97 CAP demonstrated 91% feasibility in supine and 80% in lateral position. UGAP showed 100% feasibility for all examination techniques. The whole group was divided according to steatosis stages of PDFF. When differentiating ≥ S1, CAP supine accuracy was AUC 0.81 (95%CI: 0.71-0.92), and UGAP supine/30N accuracy was 0.88 (95%CI: 0.88-0.95). Differentiating S0 and S1 vs. S2 and S3, the CAP AUC was 0.81 (95% CI: 0.72-0.90), and the UGAP supine/30 N AUC was 0.93 (95%CI: 0.88-0.99). When differentiating S0, S1, and S2 vs. S3, the CAP AUC was 0.90 (95%CI: 0.83-0.97), and the UGAP supine/4N AUC was 0.97 (95%CI: 0.94-1.00). UGAP increased performance in both sexes using increased probe force.

CONCLUSIONS: UGAP provides absolute feasibility and higher diagnostic performance. CAP should not be performed in left position.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты