MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pcd.2026.04.007

Медицинская библиотека · Primary care diabetes · 2026

Comparative assessment of diagnostic agreement between artificial intelligence and general practitioners in diabetic retinopathy screening using non-mydriatic fundus photography.

Alcalá-Millán María, Romero-Vigara Juan Carlos, Trillo-Calvo Eva

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: To assess the diagnostic agreement between an artificial intelligence (AI) system and general practitioners (GPs) interpreting fundus photographs for diabetic retinopathy (DR) screening, using the ophthalmologists' assessment as the reference standard.

METHODS

We performed a cross-sectional study of 500 primary care patients with type 2 diabetes (T2DM). Each underwent two 45° non-mydriatic fundus photos per eye. Images were independently evaluated by three trained GPs, a deep learning-based AI system (EyeArt v3.0.0 (Eyenuk Inc.)), and an ophthalmologist (reference standard). Diagnostic agreement was measured with Cohen's kappa and Cramer's V, and sensitivity, specificity, predictive values, likelihood ratios, and overall accuracy were calculated.

RESULTS

Mean age was 64 years, and 59% were men. DR prevalence was 11%. AI showed near-perfect agreement with ophthalmology (κ = 0.91) and outperformed GPs, with 98.2% sensitivity, 98.9% specificity, and 98.8% accuracy. GPs showed substantial agreement (κ = 0.84), with lower sensitivity (86.4%) but similarly high specificity (98.1%). In multinomial analysis, AI achieved 87.6% sensitivity for mild DR and 100% for moderate-to-severe DR, missing no clinically relevant cases.

CONCLUSIONS

In this cohort restricted to gradable images, AI demonstrated higher sensitivity, specificity, and diagnostic agreement than GPs when compared with a single ophthalmologist reference standard. Supervised use in primary care could strengthen population-based screening, but large-scale adoption will require multicentre studies, formal cost-effectiveness analyses, and validation in unselected screening populations.

Для цитирования: Alcalá-Millán María, Romero-Vigara Juan Carlos, Trillo-Calvo Eva. Comparative assessment of diagnostic agreement between artificial intelligence and general practitioners in diabetic retinopathy screening using non-mydriatic fundus photography.. Primary care diabetes. 2026. DOI: 10.1016/j.pcd.2026.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.