Consensus Guidelines for Delineation of Clinical Target Volumes for Intensity Modulated Radiation Therapy for Intact Cervical Cancer: An Update.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fields Emma C, Bosch Walter R, Albuquerque Kevin V, Bhatia Rohini, Chino Junzo, Dyer Brandon, Erickson Beth, Fabian Denise, Gaffney David, Glaser Scott, Han Kathy, Hathout Lara, Hsu I-Chow, Jegadeesh Naresh, Kahn Jenna, Kidd Elizabeth, Klopp Ann, Leung Eric, Lin Lilie, Ludwig Michelle, Ma Tianjun, Mell Loren, Mayadev Jyoti, Petersen Ivy, Portelance Lorraine, Rash Dominique, Taunk Neil, Viswanathan Akila, Wolfson Aaron, Yashar Catheryn, Yeung Anamaria, Yoshida Emi, Fisher Christine M
Аннотация
METHODS AND MATERIALS: Twenty-eight experts in gynecologic radiation oncology contoured 3 cases, first on a noncontrast CT simulation scan and then with registered diagnostic scans. The cases included (1) International Federation of Gynecology and Obstetrics (FIGO) IIIC1 with a bulky tumor and vaginal metastasis, (2) FIGO IIB with calcified uterine fibromas, and (3) FIGO IIIC2 with large lymph nodes. The contours on all 6 data sets (3 CT simulations without diagnostic images and 3 with registered images) were analyzed for consistency of delineation using an expectation-maximization algorithm for simultaneous truth and performance level estimation with kappa statistics as a measure of agreement. The contours were reviewed, discussed, and edited in a group meeting prior to finalizing.
RESULTS: Contours showed considerable agreement among experts in each of the cases, with kappa statistics from 0.67 to 0.72. For each case, diagnostic PET ± MRI was associated with an increase in volume. The largest increase was the clinical target volume (CTV) primary for case 2, with a 20% increase in volume and a 54% increase in simultaneous truth and performance level estimation volume, which may be due to variance in registration priorities. For the third case, 92.9% increased their CTVs based on the addition of the diagnostic PET scan. The main areas of variance were in determining the superior extent of CTV coverage, coverage of the mesorectum, and simulation and planning protocols.
CONCLUSIONS: This study shows the value and the challenges of using coregistered diagnostic imaging, with an average increase in volumes when incorporating MRI and PET.