MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-21-0877

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2022

Transaortic Transcatheter Aortic Valve Replacement in Patients From a Single Institution - Feasibility, Safety, and Midterm Outcomes.

Kakuta Takashi, Fukushima Satsuki, Kawamoto Naonori, Kainuma Satoshi, Tadokoro Naoki, Ikuta Ayumi, Minami Kimito, Kanzaki Hideaki, Amaki Makoto, Okada Atsushi, Irie Yuki, Takagi Kensuke, Izumi Chisato, Fujita Tomoyuki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transaortic transcatheter aortic valve replacement (TAo-TAVR) is an alternative to peripheral or transapical TAVR. The procedural feasibility, safety, and midterm outcomes of TAo-TAVR were investigated in this study.

METHODS AND

RESULTS

Eighty-four consecutive patients underwent TAo-TAVR from 2011 to 2021. Their median age was 83 years (interquartile range, 80-87 years). The Edwards SAPIEN and Medtronic CoreValve devices were used in 45 (53.6%) and 38 (45.2%) patients, respectively. The surgical approach was a right mini-thoracotomy in 43 patients (51.2%) and partial sternotomy in 4 patients (4.8%). The remaining 37 patients (44.0%) underwent full sternotomy because of concomitant off-pump coronary artery bypass grafting. VARC-3 device success was achieved in 77 patients (91.7%). Valve migration occurred in 3 patients (3.6%) using a first-generation CoreValve device, necessitating implantation of a second valve. No aortic annulus rupture, aortic dissection, or coronary orifice occlusion occurred. Conversion to surgery was required for 1 patient because of uncontrollable bleeding. Only 1 in-hospital death occurred. New pacemaker implantation was required in 6 patients (7.1%). Echocardiography at discharge showed no or trivial paravalvular leak (PVL) in 58 patients (69.0%), mild PVL in 23 (27.4%), and mild to moderate PVL in 2 (2.4%) patients. The 1- and 3-year incidence of cardiovascular death was 1.6% and 4.8%, respectively, with no structural valve deterioration.

CONCLUSIONS

TAo-TAVR is feasible and safe with satisfactory midterm outcomes using both currently available devices.

Для цитирования: Kakuta Takashi, Fukushima Satsuki, Kawamoto Naonori, Kainuma Satoshi, Tadokoro Naoki, Ikuta Ayumi, Minami Kimito, Kanzaki Hideaki, Amaki Makoto, Okada Atsushi, Irie Yuki, Takagi Kensuke, Izumi Chisato, Fujita Tomoyuki. Transaortic Transcatheter Aortic Valve Replacement in Patients From a Single Institution - Feasibility, Safety, and Midterm Outcomes.. Circulation journal : official journal of the Japanese Circulation Society. 2022. DOI: 10.1253/circj.cj-21-0877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.