BACKGROUND

The use of covered stents (CVS) in congenital heart disease (CHD) interventions is increasing but intrinsic properties of commercially available material remain not optimal. The Optimus-CVS™ (AndraTec GmbH, Koblenz, Germany) is a new balloon-expandable, non-premounted, Cobalt-Chromium stent with patented hybrid-cell design, innovative end-free Nano-PTFE sandwich-covering, and competitive deliverability features.

METHODS AND

RESULTS

Three patients with CHD received Optimus-CVS during December 2020 at our institution. Indications for CVS implantation were relief of complex aortic recoarctation (57 ​mm long Optimus-CVS-XL), treatment of intra-stent intimal proliferation in Fontan circulation (48 ​mm long Optimus-CVS-XXL), and as a bail-out for conduit rupture during pulmonary valve implantation (33 ​mm long Optimus-CVS-XXL). Procedures were successful and straightforward. Target diameter was achieved and stent shortening was minimal and as expected. No stent failure was recorded on short-term follow-up.

CONCLUSIONS

Optimus-CVS appears to be a reliable high-performing CVS alternative in major CHD situations where CVS are needed. Optimus-CVS offers interesting construction characteristics, smart covering design, and the largest portfolio in terms of diameters and length optimizing lesion care and improving outcomes.

Для цитирования: Haddad Raymond N, Bonnet Damien, Alsac Jean-Marc, Malekzadeh-Milani Sophie. Promising PTFE-coating technology of Optimus-CVS™ stents: The new player for congenital heart disease interventions.. International journal of cardiology. Congenital heart disease. 2022. DOI: 10.1016/j.ijcchd.2022.100323.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.