The Dilution Paradox in Extracellular Vesicle Flow Cytometry.

Rops Joyce, Buntsma Naomi, Gąsecka Aleksandra, de Rond Leonie, Nossent Anne Yaël, Kruyt Nyika D, Nieuwland Rienk, van der Pol Edwin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Concentrations of extracellular vesicles (EVs) can be measured by flow cytometry, which detects fluorescence and light scattering signals from single particles. To ensure single particle detection, plasma samples are diluted based on their particle concentration, which can differ 100-fold between samples. Here we studied how sample dilution affects EV detection by flow cytometry. EVs were measured in human plasma (i) with different concentrations of spiked-in purified lipoproteins, (ii) at different dilutions, and (iii) using either scatter-triggering or fluorescence-triggering. In addition, the reliability of two published clinical EV studies was evaluated using an analytical model. Our results show that the minimum dilution factor to prevent swarm detection by the light scattering detector can exceed the maximum dilution factor that ensures labelled EVs outnumber fluorescent background events. This 'dilution paradox' precludes reliable detection of both fluorescence and light scattering signals of EVs for some samples. In the two clinical studies, 30% and 65% of the measurements were unreliable, depending on the label used. Therefore, results from previous studies should be re-evaluated. The dilution paradox might be overcome by using fluorescence-triggering at a fixed sample dilution, removing non-EV particles from the sample, removing fluorescent particulates from staining reagents, and setting stricter inclusion criteria.

Для цитирования: Rops Joyce, Buntsma Naomi, Gąsecka Aleksandra, de Rond Leonie, Nossent Anne Yaël, Kruyt Nyika D, Nieuwland Rienk, van der Pol Edwin. The Dilution Paradox in Extracellular Vesicle Flow Cytometry.. Journal of extracellular vesicles. 2026. DOI: 10.1002/jev2.70312.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.