To what extent does prior antimicrobial therapy affect the diagnostic performance of radiolabeled leukocyte scintigraphy in infective endocarditis?

Holcman Katarzyna, Rubiś Paweł, Ćmiel Bogdan, Ząbek Andrzej, Boczar Krzysztof, Szot Wojciech, Kalarus Zuzanna, Graczyk Katarzyna, Hanarz Maksymilian, Małecka Barbara, Podolec Piotr, Kostkiewicz Magdalena

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: This prospective, single-center study sought to assess to what extent there is interference between the hybrid technique of single-photon emission tomography-computed tomography with technetium99m-hexamethylpropyleneamine oxime-labeled leukocytes (99mTc-HMPAO-SPECT/CT) and antimicrobial therapy in patients with infective endocarditis (IE).

METHODS AND

RESULTS

During the years 2015-2019, we enrolled 205 consecutive adults with suspected IE, all underwent 99mTc-HMPAO-SPECT/CT. The study population was divided into those who had received antimicrobial therapy up to 30 days prior to 99mTc-HMPAO-SPECT/CT (group 1, n = 96) and those who had not (group 2, n = 109). Patients were prospectively observed for 12 ± 10 months. Group 1 presented higher positive predictive values (91.89% vs. 60.00%, = 0.001), and decreased negative predictive values (77.97% vs. 90.54%, P = 0.04). Patients treated with antimicrobial therapy displayed false-negative 99mTc-HMPAO-SPECT/CT results more often [odds ratio (OR), 4.63; 95% confidence interval (CI), 1.41-15.23, P = .01], particularly when intravenous (OR 5.37; 95% CI 1.73-16.62, P = .004), definite (OR 9.43; 95% CI 2.65-33.51, P = .001), and combination antibiotic regimens (OR 8.1; 95% CI 2.57-25.64, P = .001) had been administered.

CONCLUSION

Prior antibiotic therapy affects 99mTc-HMPAO-SPECT/CT diagnostic properties. Patients treated with antimicrobial therapy display false-negative 99mTc-HMPAO-SPECT/CT results more often, especially if intravenous, definite, or combination regimens are administered.

Для цитирования: Holcman Katarzyna, Rubiś Paweł, Ćmiel Bogdan, Ząbek Andrzej, Boczar Krzysztof, Szot Wojciech, Kalarus Zuzanna, Graczyk Katarzyna, Hanarz Maksymilian, Małecka Barbara, Podolec Piotr, Kostkiewicz Magdalena. To what extent does prior antimicrobial therapy affect the diagnostic performance of radiolabeled leukocyte scintigraphy in infective endocarditis?. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2022. DOI: 10.1007/s12350-022-03048-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.